STANFORD RESEARCH SYSTEMS DG535 CALIBRATION and STANFORD RESEARCH SYSTEMS DG535 REPAIR

The STANFORD RESEARCH SYSTEMS DG535 is currently in stock and available for purchase on our  Sales Page
It is also available for immediate rental.
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the STANFORD RESEARCH SYSTEMS DG535 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Pulse Generator?
Shop for Comparable Products on our
 used Pulse Generator page or new Pulse Generator page

 
   STANFORD RESEARCH SYSTEMS DG535   Description / Specification:    
STANFORD RESEARCH SYSTEMS DG535 4 Ch Digital Delay and Pulse Generator

The SRS DG535 Digital Delay and Pulse Generator provides four precisely-timed logic transitions or two independent pulse outputs. The delay resolution on all channels is 5 ps, and the channel-to-channel jitter is typically 50 ps. Front-panel BNC outputs deliver TTL, ECL, NIM or variable level (-3 to +4 V) pulses into 50 O or high impedance loads. The high accuracy, low jitter, and wide delay range make the DG535 ideal for laser timing systems, automated testing, and precision pulse applications. The SRS DG535 has four delay output channels: A, B, C and D. The logic transitions of these outputs can be delayed from an internal or external trigger by up to 1000 seconds in 5 ps increments. The T0 pulse, which marks the beginning of a timing cycle, is generated by the trigger signal. The insertion delay between an external trigger and the T0 pulse is about 85 ns. Specifications. Delays; Channels: Four independent delay outputs : A, B, C and D. Range: 0 to 999.999,999,999,995 seconds. Resolution: 5 ps. Accuracy: 1500 ps + timebase error x delay. Timebase Standard: 25 ppm crystal oscillator. Timebase Optional: 1ppm TCXO (Opt. 03). Timebase External: user provides 10.0 MHz reference. Internal Rate Generator; Rate: Single shot, .001 Hz to 1.000 MHz, or Line. Resolution: 0.001 Hz below 10 Hz, otherwise 4 digits. Accuracy: Same as timebase. Jitter: 1:10,000. Settling: <2 seconds for any rate change. Input External Trigger; Rate: dc to 1/(1 µs + longest delay). Threshold: ±2.56 Vdc. Slope: Trigger on rising or falling edge. Impedance: 1 M-ohm + 40 pF or 50 ohm. Interface: IEEE488 Standard GPIB. Option 06, TTL front panel trigger inhibit input. Option 03, 1ppm TCXO. Option 02, Rear panel T0, A, B, C, D outputs.



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the STANFORD RESEARCH SYSTEMS DG535. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your STANFORD RESEARCH SYSTEMS DG535 CALIBRATION and/or STANFORD RESEARCH SYSTEMS DG535 4 Ch Digital Delay and Pulse Generator REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: