ILX LIGHTWAVE FOS-79800D REPAIR and ILX LIGHTWAVE FOS-79800D CALIBRATION

 
Custom-Cal has a high success rate in the repair of the ILX LIGHTWAVE FOS-79800D. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ILX LIGHTWAVE FOS-79800D Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Laser Source (DFB-LD-WDM-BBS)?
Shop for Comparable Products on our
 used Laser Source (DFB-LD-WDM-BBS) page or new Laser Source (DFB-LD-WDM-BBS) page

 
   ILX LIGHTWAVE FOS-79800D (79800D)   Description / Specification:    
ILX LIGHTWAVE FOS-79800D WDM DFB Fiber Optic Source Module Series

The ILX Lightwave FOS79800D Series WDM DFB Fiber Optic Source Modules are designed for the most demanding WDM system and component test applications. The 315X1 Series Source Modules supply a minimum of 10 dBm output power, while the 315X2 Source Modules supply a minimum of 13 dBm. The modules permit user-selected center wavelengths from 1528 nm to 1610 nm on ITU grid points or the user's custom specification.
Specifications.

Wavelength Output Power: 1528 to 1610 nm (module dependent).
Level at full power: >= 10 dBm or >= 13 dBm.
Attenuation Calibrated Range: 10 dB.
Available Center Wavelength: C-band or L-band.
Accuracy: ±0.05 nm. Tuning Range: ±0.85 nm.
Spectral Width Coherence Control OFF: <30 MHz.
Spectral Width Coherence Control ON: 1 GHz (typical).
Transition Time Off to On: 30 ms, On to Off: 10 ms. 
Repeatability: ±0.01 dB.
Lifetime: >10 million cycles.
SMSR: >40 dB (>45 dB typical).
Signal to Background: >30 dB.
Optical Isolation: >30 dB.
Relative intensity noise (RIN): -145 dB/Hz.
Modulation Frequency: 1 to 500 kHz.



 

Standard Calibration $405.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ILX LIGHTWAVE FOS-79800D. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Coherence Length
Average distance over which superimposed waves lose their phase relationships

Linewidth
Linewidth is the width of a spectral line in terms of wavelength, wave number and frequency.

Power Flatness Versus Wavelength
When changing the wavelength at constant power setting and recording the differences between actual and displayed power levels, the power flatness is ± half the span (in dB) between the maximum and the minimum of the measured power levels.

Spectral Width
Spectral Width is the wavelength interval over which the magnitude of all spectral components is equal to or greater than a specified fraction of the magnitude of the component having the maximum value. In optical communications applications, the usual method of specifying spectral width is the full width at half maximum. This is the same convention used in bandwidth, defined as the frequency range where power drops by less than half (at most -3 dB).

Telecom Bands
Optical fiber communications typically operate in a wavelength region corresponding to one of the following Bands. O Band (original): 1260–1360 nm. E Band (extended): 1360–1460 nm. S Band (short wavelengths): 1460–1530 nm. C Band (conventional): 1530–1565 nm. L Band (long wavelengths): 1565–1625 nm. U Band (ultralong wavelengths): 1625–1675 nm


Please contact us for your ILX LIGHTWAVE FOS-79800D REPAIR and/or ILX LIGHTWAVE FOS-79800D WDM DFB Fiber Optic Source Module Series CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: