ACTERNA OLP-18B CALIBRATION and ACTERNA OLP-18B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ACTERNA OLP-18B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Optical Power Meter?
Shop for Comparable Products on our
 used Optical Power Meter page or new Optical Power Meter page

 
   ACTERNA OLP-18B   Description / Specification:    
ACTERNA OLP-18B 800 to 1700 nm Handheld Optical Power Meter

The Acterna OLP-18B Optical Power Meter is especially suitable for applications involving the installation, maintenance or repair of fiber optics networks, as they are both compact and easy to use. It can be used to make power and loss measurements in the wavelength range from 800 to 1700 nm. The OLP-18B is specially suited to measuring high power levels, such as those found in CATV systems, optical amplifiers (e.g. EDFA) and high-power lasers. The upper display limit for the OLP-18B is +26 dBm. The lower limit of below -60 dBm means that the instruments are suitable for practically any application. The OLP-18B can store up to 150 sets of data and output these to a PC or printer for documentation via the built-in RS 232 interface. Specifications. Wavelength range: 800 to 1700nm. Photodiode: InGaAs. Fiber type: 9/125 to 500/125 um. Standard wavelengths, switchable: 850,980,1310,1480, 1550, 1625 nm. Display range: -60 to +26 dBm. Max. permitted level: +26 dBm. Intrinsic error: ± 0.13 dB (corresponds to ±3%). Overall measurement uncertainty for the level range -50 to +23 dBm: + 0.33 dB +10 nW (850 nm), ±0.25 dB ±2 nW (1300,1310 nm), ±0.25 dB ±2 nW (1550 nm). Wavelength detection: automatic switching and display of nominal wavelength. Data memory: 1000 results. Results data/Remote control: RS 232 interface. Modulation detection: 270 Hz, 330 Hz, 1 kHz, 2 kHz. Result display: LCD, 4-digit. Resolution: 0.01 dB/0.001 uW.



 

Standard Calibration $220.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ACTERNA OLP-18B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Amplified Spontaneous Emission Source (ASE)
ASE, a process where spontaneously emitted radiation (luminescence) is amplified. In lasers and particularly in high-gain erbium-doped amplifiers, amplified spontaneous emission is usually an unwanted effect. It tends to limit the gain achievable in a single stage of a fiber optic amplifier to the order of 40–50 dB.

Dynamic Range
In a transmission system, the ratio of the overload level to the noise level of the system, usually expressed in dB. Ratio of the highest to lowest detectable signal of a system, expressed in dB.

Optical Power
Optical Power is usually measured in "dBm", or decibels referenced to one miliwatt of power. while loss is a relative reading, optical power is an absolute measurement, referenced to standards. You measure absolute power to test transmitters or receivers and relative power to test loss.

Relative Wavelength Accuracy
When randomly changing the wavelength and measuring the differences between the actual and displayed wavelengths, the relative wavelength accuracy is ± half the span between the maximum and the minimum value of all differences.

Wavelength
Wavelength is a term for the color of light, usually expressed in nanometers (nm) or microns (m). In Fiber Optics the wavelenghts mostly used are in the infrared region where the light is invisible to the human eye.


Please contact us for your ACTERNA OLP-18B CALIBRATION and/or ACTERNA OLP-18B 800 to 1700 nm Handheld Optical Power Meter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: