ILX LIGHTWAVE LPA-9072B REPAIR and ILX LIGHTWAVE LPA-9072B CALIBRATION

 
Custom-Cal has a high success rate in the repair of the ILX LIGHTWAVE LPA-9072B. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ILX LIGHTWAVE LPA-9072B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Laser Diode Controller?
Shop for Comparable Products on our
 used Laser Diode Controller page

 
   ILX LIGHTWAVE LPA-9072B (LPA 9072B)   Description / Specification:    
ILX LIGHTWAVE LPA-9072B Laser Diode Parameter Analyzer

The ILX Lightwave LPA-9072B Laser Diode Pararneter Analyzer tests laser diodes/LEDs operating from 0 to 500. It can generate L/I, V/I, L/lm and dL/dl parametric data with 16-bit resolution in 10 seconds or less. Up to 10 sets of data can be compiled and presented in both graphical and tabular form. Data can be shared with other applications or easily output to a high-resolution printer. Specifications. Current Output; Maximum Current: 200 mA / 500 mA. Current Limit Range: 0 to 202 mA / 0 to 505 mA. Current Limit Resolution:1 mA on 200 mA range / 2 mA on 500 mA range. Set Point Resolution: 16 bit (4 µA / 10 µA). Set Point Accuracy (% of FS): ±0.05%. Compliance Voltage: 6.5V. Forward Voltage Measurement; Range: 0 to 7.0 V. Accuracy: ±2 mV. Photodetector Amplifier; PD Current Range: 10 nA to 50 mA. Accuracy (% of FS): ±5% (10 nA to 500 nA), ±1 % (500 nA to 50 mA). Short Term Repeatability @ 25 C: ±0.5% (10 nA to 500 nA), ±1 % (500 nA to 50 mA). Back Facet Monitor; Range: 1 µA to 5,000 µA. Accuracy (% of FS): ±0.05%. Reverse Bias: 0 to -5 V, adjustable. Stability (24 hr period): ±0.02%. Temperature Control; Range: -99.9°C to + 199.9°C. Resolution: 0.1°C. Thermistor Set Point Accuracy: ±0.2°C from 0°C to +50°C. TE Control: Bipolar, constant current source.



 

Standard Calibration $720.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ILX LIGHTWAVE LPA-9072B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Chromatic Dispersion
Chromatic Dispersion is a broadening of the input signal as it travels down the length of the fiber. Chromatic Dispersion results from a variation in propagation delay with wavelength, and is affected by fiber materials and dimensions.

Detector
A Detector is a signal conversion device that converts power from one form to another, such as from optical power to electrical power

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Polarization Mode Dispersion (PMD)
Polarization mode dispersion (PMD) is a form of modal dispersion where two different polarizations of light in a waveguide, which normally travel at the same speed, travel at different speeds due to random imperfections and asymmetries, causing random spreading of optical pulses. It is he difference between the maximum and minimum values of loss typically measured in ps/km^1/2.


Please contact us for your ILX LIGHTWAVE LPA-9072B REPAIR and/or ILX LIGHTWAVE LPA-9072B Laser Diode Parameter Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: