DATRON 4808 REPAIR and DATRON 4808 CALIBRATION

 
Custom-Cal has a high success rate in the repair of the DATRON 4808. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the DATRON 4808 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Calibrator?
Shop for Comparable Products on our
 used Calibrator page

 
   DATRON 4808   Description / Specification:    
DATRON 4808 Multifunction DMM Calibrator

The Datron 4808 Multifunction DMM Calibrator is designed to be supported by the 4950 Multifunction Transfer Standard. DC Voltage (Option 10); Ranges: 100 uV to 1000V in decades. Resolution: 7 1/2 digits or 10 nV, whichever is greater. Output Impedance/Max Output Current: 100 uV to 100 mV Ranges, 100 ohm. 1V to 1000V Ranges, 25 mA max.AC Voltage (Option 20); Ranges: 1 mV to 1000V in decades. Resolution: 6 1/2 digits or 100 nV, whichever is greater. Frequency: Ranges: 10 Hz to 1 MHz. Resolution: 1% of setting or 1Hz. Accuracy: <±100 ppm. Maximum Capacitive load: 1000 pF on 1V to 100V ranges, 300 pF on 1000V range. DC Current (Option 40); Ranges: 100 uA to 10A in decades. Resolution: 6 1/2 digits or 100 pA, whichever is greater. AC Current (Option 40); Ranges: 100 mA to 10A in decades. Resolution: 6 1/2 digits or 100 pA. whichever is greater. Resistance (Option 50); Ranges: 10 ohms to 100 Mohm in decades. (Ranges are nominal, actual calibrated values are displayed). Connections: Selectable 2 or 4-wire, remote/local guard. Display Resolution: 7 1/2 digits. IEEE-488 interface. OPTIONS; 10: DCV Ranges to 200V. 20: ACV Ranges to 200V. 30: 1000V range for DCV, ACV (requires option 10, option 20 or both). 40: DCI and ACI to 2A (requires option 10, option 20 or both). 50: Ohm Ranges. 60: DCI and ACI ranges extender to 11A DC or RMS AC (requires Options 10 and/or 20 and option 40).



 

Standard Cal with Data $1,540.00 *
*This is a Web introductory price for one calibration of the DATRON 4808. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your DATRON 4808 REPAIR and/or DATRON 4808 Multifunction DMM Calibrator CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: