FLUKE 185 CALIBRATION and FLUKE 185 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 185 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   FLUKE 185   Description / Specification:    
FLUKE 185 Handheld True RMS Digital Multimeter

The Fluke 185 is a Handheld True RMS Digital Multimeter featuring AC+DC true RMS measurements, 50.000 counts resolution and a 0.05% basic DC accuracy. The extra large dual display with analog bar graph and backlight ensure that readings are easy to read under all circumstances. The unit offers measurements of dB, temperature, a 4-20mA process loop percentage readout, min-max-average recording with timestamp, up to 30 readings, memories and a computer interface. The computer interface can also be used to perform closed case calibration and when the batteries run down you do not have to open the complete case and break the calibration seal to exchange them.
Specifications.

Voltage DC.
  Max: 1000 V.
  Max Resolution: 1 µV to 10 µV.
  Accuracy: ±(0.05%+1).

Voltage AC.
  Max: 1000 V.
  Max Resolution: 1 µV.
  Accuracy: ±(0.4%+2).

Current DC.
  Max: 10 A.
  Max Resolution: 0.01 µA.
  Accuracy: ±(0.2%+2).

Current AC.
  Max: 10 A.
  Max resolution: 0.01 µA ±(0.6%+2).

Resistance.
  Max: 50 MΩ to 500 MΩ.
  Max Resolution: 0.01 Ω.
  Accuracy: ±(0.1%+2).

Conductance.
  Max: 500 nS.
  Max Resolution: 0.01 nS.

Capacitance.
  Max: 50000 µF.
  Max Resolution: 0.001 nF.
  Accuracy: ±(1.0%+3).

Frequency.
  Max: 1 MHz.
  Max Resolution: 0.001 Hz.
  Accuracy: ±(0.002%+1).

Temperature.
  Max: -50°C/+980°C ; -200°C/+1350°C.
  Max Resolution: 0.1°C.

dBm and dBV.
  Max: -52/+60 dB ; -74/+60 dB
  Max Resolution: 0.01 dB.



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bandwidth
Bandwidth is the difference between the upper and lower frequencies in a contiguous set of frequencies within which a component, link or network will operate.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Noise Figure
Noise Figure the ratio of the signal-to-noise power ratio at the input to the signal-to-noise power ratio at the output.

Ringing
Ringing is an unwanted oscillation of a voltage or current.


Please contact us for your FLUKE 185 CALIBRATION and/or FLUKE 185 Handheld True RMS Digital Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: