ADVANTEST Q7606B CALIBRATION and ADVANTEST Q7606B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ADVANTEST Q7606B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Lightwave Measurement System?
Shop for Comparable Products on our
 used Lightwave Measurement System page or new Lightwave Measurement System page

 
   ADVANTEST Q7606B   Description / Specification:    
ADVANTEST Q7606B Optical Chirpform Test Set

The Advantest Q7606B Optical Chirpform Test Set is a lightwave modulation test set, used together with a digital sampling oscilloscope, to separately measure and evaluate the chirp (frequency-modulated / FM) and intensity-modulated (IM) components of incident laser light. The Q7606B contains two sets of fiber-type Mach-Zehnder interferometers and their control circuits. The Q7606B can selectively output the sum of, or difference between the frequency-modulated / FM and IM components of the modulated incident light by switching the measurement mode. The sum (IM+FM) and difference (lM-FM) data are processed by the digital sampling oscilloscope and the personal computer to separate the chirp FM and IM components from each other, thus making it possible to evaluate the time-domain charactenstics. Specifications. Wavelength measurement range: 1510 to 1590 nm. Optical input power range: -20 to 10 dBm. Free Spectral Range: 150 GHz ±15 GHz. Demodulation band width (130 MHz as standard, 1 dB down):100 Hz to 50 GHz. Deviation of demodulation frequency: 65 GHz p-p or less. Resolution of demodulation frequency (Depends on the measurement resolution of an external sampling oscilloscope and input optical power.: 20 MHz p-p or less. Insertion Loss: 10 dB or less. Optical output power (Depends on the input optical power.): Input cal power (dBm) -10 dB or higher. Input light polarization compensation: Automatically controlled.



 

Standard Calibration $1,835.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ADVANTEST Q7606B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
Optical power referenced to 1 millimatt

Multimode Fiber
Multimode Fiber has a large core (almost always 62.5 microns - a micron is one one millionth of a meter - but sometimes 50 microns) and is used with LED sources at wavelengths of 850 and 1300 nm for short distance, lower speed networks like LANs. Both multimode and singlemode fiber have an outside diameter of 125 microns - about 5 thousandths of an inch - just slightly larger than a human hair.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Refractive Index
The refractive index or index of refraction of a substance is a measure of the speed of light in that substance. It is expressed as a ratio of the speed of light in vacuum relative to that in the considered medium. The velocity at which light travels in vacuum is a physical constant, and the fastest speed at which energy or information can be transferred. However, light travels slower through any given material, or medium, that is not vacuum.

Total insertion loss
A measure of the loss of light within an optical component


Please contact us for your ADVANTEST Q7606B CALIBRATION and/or ADVANTEST Q7606B Optical Chirpform Test Set REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: