TEKTRONIX 80A05 CALIBRATION and TEKTRONIX 80A05 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX 80A05 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope Plug In?
Shop for Comparable Products on our
 used Oscilloscope Plug In page

 
   TEKTRONIX 80A05   Description / Specification:    
TEKTRONIX 80A05 20 GHz Electrical Clock Recovery Module

The Tektronix 80A05 Electrical Clock Recovery Module will recover the clock from electrical data for all Tektronix electrical modules. The 80A05 Electrical Clock Recovery Module provides a solution for triggering the main instrument from single-ended or differential electrical signals. The 80A05 can also be used as a general purpose clock recovery solution. Mainframe interface: Tekprobe-Sampling, Level 3, Hot switching is not permitted. Number of inputs: 2. Input and output connectors: SMA. Data input/output coupling: DC. Maximum non-destruct range either inputs: 2.5 Vp-p. Maximum operating range single-ended operation either input: 2.0 Vpk-pk. Maximum operating range complementary operation each input: 1 Vp-p. Maximum DC offset: ±2.0 VDC. Electrical Return Loss Data in+, data in--,data out+, data out--: 15 dB or better (DC to 10GHz), 10dB or better (10GHz to 20GHz). Electrical data attenuation DC to 12.5 GHz: 6.6 dB ±0.6 dB. Propagation delay either inputs: 875 ps. Input/output impedance: 50 ohm. Analog bandwidth: ±3 dB, DC to 20 GHz. Recovered clock timing jitter: < 1.0% of unit interval (50 Mb/s to 2.7 Gb/s), < 2.5 ps RMS (2.7 Gb/s to 6.375 Gb/s), < 2.0 ps RMS (9.8 Gb/s to 12.6 Gb/s). Minimum clock recovery sensitivity Single-ended operation: 10 mVp-p (150 Mb/s to 2.7 Gb/s), 15 mVp-p (2.7 Gb/s to 11.19 Gb/s), 20 mVp-p (11.19 Gb/s to 12.5 Gb/s). Supported data rates and formats (without Option 10G): OC3/SMT1 155.52 Mb/s OC12/STM4 622.08 Mb/s, FibreChannel 1.063 Gb/s, Gigabit Ethernet 1.25 Gb/s, Serial ATA 1.5 Gb/s, 2 Gigabit FibreChannel 2.125 Gb/s, OC48/STM16 2.488 Gb/s, 2 Gigabit Ethernet 2.5 Gb/s, InfiniBand 2.5 Gb/s, PCI Express 2.5 Gb/s, 2.5G G.709 FEC 2.666 Gb/s, Serial ATA 3.0 Gb/s, XAUI 3.125 Gb/s, FibreChannel 3.188 Gb/s, VSR5 3.318 Gb/s, 4 Gigabit FibreChannel 4.25 Gb/s. Supported user selected clock recovery (without Option 10G): 50 Mb/s to 2.7 Gb/s, 3.000 Gb/s to 3.188 Gb/s. Option 10G adds supported data rates and formats: Serial ATA 6.0 Gb/s, XAUI 6.25 Gb/s, OC192/STM64 9.953 Gb/s, 10GBase-W 9.953 Gb/s, 10GBase-R 10.31 Gb/s, 10G FibreChannel 10.51 Gb/s, G.975 FEC 10.66 Gb/s, G.709 FEC 10.71 Gb/s, 10GbE w/FEC 11.10 Gb/s, Super FEC 12.50 Gb/s. Option 10G adds supported user selected clock recovery: 50 Mb/s to 3.188 Mb/s, 3.267 Gb/s to 4.250 Gb/s, 4.900 Gb/s to 6.375 Gb/s, 9.800 Gb/s to 12.60 Gb/s.



 

Standard Calibration $605.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX 80A05. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your TEKTRONIX 80A05 CALIBRATION and/or TEKTRONIX 80A05 20 GHz Electrical Clock Recovery Module REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: