BK PRECISION 1621A CALIBRATION and BK PRECISION 1621A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BK PRECISION 1621A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   BK PRECISION 1621A   Description / Specification:    
BK PRECISION 1621A 18V 5A Single Output Digital Display DC Power Supply

The BK Precision 1621A 0 to 18V, 0 to 5A Digital Display DC Power Supply has both coarse and fine voltage and current control knobs and dual LED displays to continuously monitor both output current down to 10 mA and voltage down to 100 mV. Features; Continuously monitor voltage and current output on two digital meters. Connect two supplies in parallel to double the current output. Connect two supplies in series to double the voltage output. Operate continuously at full load without overheating. Fully overload protected. Coarse and fine voltage controls. Constant voltage or constant current operation. Specifications. Output Voltage: 0 to 18 V. Output Current: 0 to 5 A. Constant Voltage Operation Voltage Regulation Line (120VAC ±10%, -6%): <= 0.02% + 3 mV. Voltage Regulation Load (no load - full load): <= 0.02% + 3 mV. Recovery Time: <= 500 ms. Ripple & Noise: 0.5 mVrms (Typical). Temperature Coefficient: <= 300 ppm/°C. Constant Current Operation Adjustable Current Limit: 0-100%. Current Regulation Line (120VAC ±10%): <= 0.02% + 3 mA. Current Regulation Load: <= 0.02% + 3 mA. Current Ripple: <= 3 mA. Metering Type: Dual 3-digit LED. Voltmeter Range: 0-18 V. Voltmeter Accuracy: ±0.2% +2 digits. Ammeter Range: 0-9.99 A. Ammeter Accuracy: ±0.2% +2 digits. Overload Protection Current, limiting, reverse polarity, overvoltage, short circuit.



 

Standard Calibration $115.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BK PRECISION 1621A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your BK PRECISION 1621A CALIBRATION and/or BK PRECISION 1621A 18V 5A Single Output Digital Display DC Power Supply REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: