BK PRECISION 2704C CALIBRATION and BK PRECISION 2704C REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BK PRECISION 2704C Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   BK PRECISION 2704C   Description / Specification:   Spec Sheet 
BK PRECISION 2704C Manual Ranging Tool Kit DMM with Transistor Test

The B+K Precision 2704C Manual Ranging Tool Kit DMM with Transistor Test has all of the functionality for basic DMM applications including some high end features you might not expect. The 2000 count LCD can display resistance values up to 2 G-ohm, capacitance to 20 uF or a transistors common-emitter gain value up to 1000. Specifications. DC Volts Ranges: 200 mV, 2 V, 20 V, 200 V, 1000V. AC Volts (50 Hz- 500Hz) Ranges: 200 mV, 2 V, 20 V, 200 V, 750V. DC Current Ranges: 20 mA, 200 mA, 10 A. AC Current (50 Hz- 500Hz) Ranges: 20 mA, 200 mA, 10 A. Resistance Ranges: 200 ohm, 2 k-ohm, 200 k-ohm, 20 M-ohm, 2000 M-ohm. Capacitance Ranges: 2 nF , 20 nF, 200 nF, 2.0 uF, 20 uF. Frequency Ranges: 2 kHz, 20 kHz, 200 kHz, 2 MHz, 20 MHz. Diode Test Test Current: 1.0 mA (typical). Continuity Audible Indication: Less than 100 ohm. Transistor hFE Range: 0 to 1000. Logic Test Threshold: Logic Hi (2.8 V ±0.8 V) / Logic Lo (0.8 V ±0.5 V). Display: 3 1/2 digit, 2000 count LCD. Overrange: OL or -OL is displayed. Measurement Rate: 2.5 times per second.



 

Standard Calibration $80.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BK PRECISION 2704C. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your BK PRECISION 2704C CALIBRATION and/or BK PRECISION 2704C Manual Ranging Tool Kit DMM with Transistor Test REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: