A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BK PRECISION 4003A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Function Generator?
Shop for Comparable Products on our
 used Function Generator page or new Function Generator page

 
   BK PRECISION 4003A   Description / Specification:   Spec Sheet 
BK PRECISION 4003A 4 MHz Sweep Function Generator/ 20 MHz Frequency Counter

The B&K Precision 4003A 4 MHz Sweep Function Generator with Frequency Counter offers linear or log sweep with variable sweep rates and widths. It has a 20 MHz 5-digit external frequency counter. Specifications. Frequency Range: 0.5 Hz to 4 MHz in 6 Ranges. Waveforms: 6 Waveforms (Sine, Square, Triangle, Ramp, +Pulse, -Pulse). Amplitude: 0.2 Vpp - 20 Vpp (no load), 0.1 Vpp - 10 Vpp (50 ohm load). Attenuator: -20 db (±2%). Output Impedance: 50 ohm (±2%). DC Offset: ±10 V (pull ADJ.). Distortion: <2%, 1 Hz to 100 kHz. Rise/Fall Time: <90 ns. VCF Input: 0 to 10 V control. SYNC Output Rise Time: <60 ns (TTL), <90 ns (CMOS). SYNC Output Level: approx. 3 Vpp (TTL), variable 4 Vpp - 15 Vpp [±1 Vpp] (CMOS). SYNC Output Waveforms: Square, Pulse. Sweep Mode: Linear/Log Sweep. Sweep Rate: 5 s to 10 ms Continuously Variable. Sweep Output: 10 Vpp (open). Sweep Output Impedance: 1 k-ohm ±2%. Frequency Counter Range: 0.2 Hz to 20 MHz. Display: 5-digit LED display with Autorange. Resolution: 0.01 Hz. MODE: INT Function Generator/EXT Counter. Accuracy: < 0.02% ± 1 digit, for >= 1 kHz. Sensitivity: <100 mVrms (1 MHz), <200 mVrms (>1 MHz). Max Input: <150 Vrms.



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BK PRECISION 4003A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your BK PRECISION 4003A CALIBRATION and/or BK PRECISION 4003A 4 MHz Sweep Function Generator/ 20 MHz Frequency Counter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: