BK PRECISION 8514 CALIBRATION and BK PRECISION 8514 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BK PRECISION 8514 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Electronic Load?
Shop for Comparable Products on our
 used Electronic Load page

 
   BK PRECISION 8514   Description / Specification:    
BK PRECISION 8514 240A 1200W Single Input Electronic Load

The BK Precision 8514 1200 W Programmable DC Electronic Load can be used for testing and evaluating a variety of DC power sources. It's wide operating ranges of up to 120 V and 240 A, flexible operating modes and excellent measurement accuracy make the 8514 well suited for characterizing DC Power supplies, DC-DC Converters, batteries, fuel cells and solar cells. The loads can operate in CC, CV, CR or CP mode while voltage/current or resistance/power values are measured and displayed in real time. Load terminals are isolated and floating. Extensive protection, including over temperature, over power, over voltage, over current and reverse polarity will help protect your valuable prototype. The DC loads are easy to use. All parameters can be set quickly and precisely from the front panel, or programmed via RS232 (included) or USB (optional) interfaces. Specifications. Input rating Voltage: 0 to 120 V. Input rating Current: 0 to 240 A. CV Mode Regulation Range: 0.1 to 18 V (Accuracy ±(0.05%+0.02% FS), Resolution 1 mV), 0.1 V to Vmax (Accuracy ±(0.05%+0.025% FS), Resolution 10 mV). CC Mode Regulation Range: 0 to 24 A (Accuracy ±(0.1%+0.1% FS), Resolution 1 mA), 0 to max Current (Accuracy ±(0.2%+0.15% FS), Resolution 10 mA). Current Measurement Range: 0 to 24 A (Accuracy ±(0.1%+0.1% FS), Resolution 1 mA), 0 to max Current (Accuracy ±(0.2%+0.15% FS), Resolution 10 mA). Voltage Measurement Range: 0 to 18 V (Accuracy ±(0.02%+0.025% FS), Resolution 1 mV), 0 V to Vmax (Accuracy ±(0.02%+0.025% FS), Resolution 10 mV).



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BK PRECISION 8514. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your BK PRECISION 8514 CALIBRATION and/or BK PRECISION 8514 240A 1200W Single Input Electronic Load REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*