BK PRECISION 8540 CALIBRATION and BK PRECISION 8540 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BK PRECISION 8540 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Electronic Load?
Shop for Comparable Products on our
 used Electronic Load page

 
   BK PRECISION 8540   Description / Specification:    
BK PRECISION 8540 30A 150W DC Electronic Load

The B&K Precision 8540 DC electronic load (60V/30A/150W) can sink DC current in constant current, constant voltage, and constant resistance modes. Measured values have 10 mV and 1 mA resolution. Shorts can be simulated. Storage is provided for up to 100 groups, with 4 instrument setups per group. The instrument is easy to use and will find many uses for testing DC power supplies, batteries, and DC to DC converters. Specifications. Input rating Voltage: 0 to 60 V. Input rating Current: 1 mA to 30 A. CV Mode Regulation Range: 0.1 to 60 V (Accuracy ±(0.05%+0.1% FS), Resolution 10 mV). CC Mode Regulation Range: 0 to 3 A (Accuracy ±(0.1%+0.1% FS), Resolution 1 mA), 0 to 30 A (Accuracy ±(0.1%+0.15% FS), Resolution 10 mA). Current Measurement Range: 0 to 3 A (Accuracy ±(0.1%+0.1% FS), Resolution 1 mA), 0 to 30 A (Accuracy ±(0.1%+0.15% FS), Resolution 10 mA). Voltage Measurement Range: 0 to 10 V (Accuracy ±(0.05%+0.1% FS), Resolution 1 mV), 0 V to 60 V (Accuracy ±(0.05%+0.1% FS), Resolution 10 mV).



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BK PRECISION 8540. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your BK PRECISION 8540 CALIBRATION and/or BK PRECISION 8540 30A 150W DC Electronic Load REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: