A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANRITSU 54130A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   ANRITSU 54130A   Description / Specification:    
ANRITSU 54130A 20 GHz Scalar Network Analyzer

Anritsu 54130A 12.4 GHz to 20 GHz, Scalar Network Analyzer. Measurement Modes: Transmission (dB), Return Loss (dB), Precision Return Loss (dB), SWR (linear SWR), Power (dBm), optional Distance-To-Fault (feet or meters) and Relative Group Delay (ns). Analyzer; Dynamic Range: -55 dBm to +16 dBm, Autozeroing implements AC detection on a single cycle per sweep basis using Anritsu 560 Series or 5400 Series Detectors and SWR Autotesters. Inputs: Three. Two standard inputs, A and B, with an optional third reference channel, R. Channels: Two channels are used to select and simultaneously display any two inputs from A, B, or R. The inputs can also be displayed as ratios A/R or B/R. Display Resolution: Horizontal: 51, 101, 201, or 401 points; Vertical: 0.025 dB, 0.0025 ns. Vertical Scaling: Resolution: 0.1 dB(m) to 10 dB(m) per division. Independent control for each channel 0.1 to 100 ns per division. Offset range: -99.9 dB to +99.9 dB, -99.9 to +99.9 ns. Averaging: 2, 4, 8, 16, 32, 64, 128, or 256 successive traces may be averaged together to remove unwanted noise. Channels may be independently set. Source; Frequency Range: 12.4 GHz to 20 GHz. Frequency Resolution: ±100 kHz. Start Frequency Accuracy: ±200 kHz Sweep Time, Single Band: Typically less than 70 ms for single channel with 101 point horizontal resolution, depending on frequency, averaging, and smoothing settings. Trace update time is typically 130 ms with similar system settings. Power Level Accuracy: ±1 dB, leveled. ±3.0 dB for models above 20 GHz, and ± 4.0 dB for 50 GHz models. Add ±0.2 dB for Option 4-75 ohm output. Power Level Accuracy, Attenuator: Optional 70 dB Step Attenuator (10 dB steps). Leveled power accuracy degrades by ±1.5 dB. Interface: IEEE-488.2 compliant interface with integrated GPIB Plotter Control is standard. Option 2, 70 dB RF Step Attenuator. Option 5, Add Reference Channel. Option 6, Add External Leveling. Option 7, Internal Distance-To-Fault Software. Option 8, Relative Group Delay Software.



 

Standard Calibration $800.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANRITSU 54130A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Adjacent Channel Power
Adjacent Channel Power is the power from a modulated communications channel that leaks into an adjacent channel. This leakage is usually specified as a ratio to the power in the main channel, but is sometimes an absolute power.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.


Please contact us for your ANRITSU 54130A CALIBRATION and/or ANRITSU 54130A 20 GHz Scalar Network Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: