The Anritsu MS4622A 3 GHz, 2-Port, Transmission/Reflection Analyzer is a one path, two port network analyzer that satisfies high volume passive RF production requirements for stability, reliability, speed, dynamic range and accuracy. Typical Dynamic Range of 125 dB, fast Measurement Speed of 150 µsec/point. Specifications. Frequency Range: 10 MHz to 3 GHz. Source Power Range (No Options): +10 to –85 dBm. Level Accuracy: ±1 dB. Sweep Range: 20 dB Minimum. Harmonics: –30 dBc. Stability: <5 ppm / year. Receiver Average Noise, 10 Hz <3 GHz: –115 dBm. Receiver 0.1 dB Compression: +7 dBm. Receiver Maximum Input: +27 dBm. Receiver Damage Level: +30 dBm. System Dynamic Range (Terminated): 125 dB (10 to 3000 MHz). High Level Noise: <0.008 dB rms (10 to 3000 MHz). IF Bandwidth Range: 10 Hz, 30 Hz, 100 Hz, 300 Hz, 1 kHz, 3 kHz, 10 kHz, and 30 kHz. Data Points: 1, 3, 15, 51, 101, 201, 401, 801, and 1601; Arbitrarily use Discrete Fill for 2 to 1601 points. Impedance: 50 Ohms. Frequency Resolution: 1 Hz. Power Output Range: +10 to –85 dBm (2-Ports No Options). Power Control Range: >20 dB. The minimum absolute level for power sweep is -15 dBm while the maximum power output for a unit is typically +10 dBm, depending upon configuration. Power Level Accuracy: ±1 dB to 6 GHz, ±1.5 dB to 9 GHz (no flat power calibration applied; full-band frequency sweep at -15 dBm, 0 dBm, and maximum rated power). Sweep Type: Linear, CW, Marker, or N-Discrete point sweep. Liquid Crystal Display: A Color 8.4" Thin Film Transistor (TFT) LCD display. Options. 1: Rack Mount Kit. 1A: Rack Mount Kit for use with System Console. 2: Time (Distance) Domain Measurement Capability. 7: Transmission and Reflection Step Attenuator. 8: Harmonic Measurements. 13: Intermodulation Distortion (IMD). 15: Internal 500 MB Hard Drive.
|