ANRITSU S113 CALIBRATION and ANRITSU S113 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANRITSU S113 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   ANRITSU S113   Description / Specification:    
ANRITSU S113 1.2 GHz Site Master SWR/RL and Fault Location Tester

The Anritsu S113 Site Master Portable Network Analyzer is the instrument of choice for transmission line/antenna installation and maintenance. It replaces stacks of heavy, expensive, and complex test equipment. Site Master's frequency domain reflectometry technique allows it to find problems before they become catastrophic faults, thereby creating a huge cost savings. The Site Master is a precision, hand-held return loss/SWR and fault location measurement instrument. The S113 Site Master offers built-in fault location, wattmeter, and bias tee capabilities are available. Light weight, rugged design and wide temperature range make it ideal for field applications. Site Master's proprietary design provides immunity to RF interference, which is important for live site testing. Specifications. Frequency range: 5 MHz to 1200 MHz. Frequency Accuracy (CW Mode): 75 parts per million. Frequency Resolution: 10 kHz. Immunity to interfering RF signals up to: +10 dBm. Measurement Range: SWR 1.00 to 65.00, Resolution: 0.01 dB. Return Loss Range: 0.0 to 54.00 dB, Resolution: 0.01 dB. Distance-To-Fault (DTF) Range (in meters): 0 to (Resolution x 129). Maximum Input (Damage Level) +22 dBm. Options. Option 5, RF Watt Meter Power Monitor (RF detector not included).



 

Standard Calibration $380.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANRITSU S113. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.


Please contact us for your ANRITSU S113 CALIBRATION and/or ANRITSU S113 1.2 GHz Site Master SWR/RL and Fault Location Tester REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: