ANRITSU ML2408A CALIBRATION and ANRITSU ML2408A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANRITSU ML2408A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Power Meter?
Shop for Comparable Products on our
 used RF Power Meter page

 
   ANRITSU ML2408A   Description / Specification:    
ANRITSU ML2408A 2 Channel RF Power Meter

The Anritsu ML2408A 2 Channel RF Power Meter combines the advantages of thermal meter accuracy, diode meter speed, and peak power meter display graphics. The result is a single instrument that achieves 90 dB dynamic range with a single sensor. It includes graphics display capability as a standard feature. The ruggedized housing and optional high-capacity NiMH battery bring convenience and accuracy to field service applications. Specifications. Frequency range: 10 MHz to 110 GHz (sensor dependent). Power sensors: Meter specifications apply to MA2400A series Power Sensors. Compatible with Anritsu MA and MP series sensors. Sensor Dynamic Range: MA2420A Series Fast Thermal Sensors: 50 dB, MA2440A Series High Accuracy Power Sensors: 87 dB CW, MA2470A Series Power Sensors: 90 dB CW, MA2469A Power Sensor with 80 dB dymamic range. Power Measurement Range: –70 to +47 dBm (0.1 nW to 50W), sensor/attenuator dependent. Use couplers for higher power levels. Voltage Measurement Range: 0.00 to 20.00 V, nominal. Display Range: –99.999 to +99.999 dB. Display Resolution: Selectable from 0.1 dB to 0.001 dB limited to 0.01 dB in graphical display modes; Linear power units, 3 to 6 digit, 1 – 3 digits selectable to right of decimal nW – W; Voltage, 1 – 2 digits selectable to right of decimal. Display Units: dBm, dB, dBr, dBmV, dBmV, W, %, Volts. Instrument Accuracy: < 0.5 %.



 

Standard Calibration $350.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANRITSU ML2408A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.


Please contact us for your ANRITSU ML2408A CALIBRATION and/or ANRITSU ML2408A 2 Channel RF Power Meter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: