ANRITSU ML2496A CALIBRATION and ANRITSU ML2496A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANRITSU ML2496A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Power Meter?
Shop for Comparable Products on our
 used RF Power Meter page

 
   ANRITSU ML2496A   Description / Specification:    
ANRITSU ML2496A 2 Channel Pulse RF Power Meter

The Anritsu ML2496A 2 Channel Pulse RF Power Meter is suited for Wideband power measurements on signals such as W-CDMA, WLAN, and WiMAX. Several different families of power sensors are available with frequency coverage to 50 GHz and dynamic range up to 90 dB. Most of the power sensors can work in either pulsed/modulated or CW mode. PowerMax is a free graphical user-interface software that provides an enhanced visualization of instrument display and simplified remote control of the instrument. Compatible with Anritsu MA and MP series sensors. Specifications. Frequency range: 100 kHz to 65 GHz (sensor dependent). Dynamic range: –70 to +20 dBm (dependent on sensor, external coupler or attenuator). Sampling rate CW Mode: 75 kS/s. Sampling rate Pulse/Modulated Mode: 31.25 kS/s to 62.5 MS/s Continuous Sampling (Trigger capture time 3.2 µs to 7s, 200 data points). System rise-time (10% to 90% at +10 dBm): Typical 8 ns, Maximum 12 ns (with MA2411B sensor). Rise-time measurement dynamic range: 10% to 90% Rise-time measurement of –20 dBm to +20 dBm Peak power (with MA2491A). Source sweep: Single channel power sweep or frequency sweep. Display resolution in Readout mode: 0.1 to 0.001 dB. Measurement hold: Hold, Max, Min. Measurements: Average, Min, Max, Peak, Crest, PAE (Power Added Efficiency). Voltage measurement range: 0.00 to 20.00V nominal. Display range: –199.99 to +199.99 dB. Display: Color LCD.



 

Standard Calibration $350.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANRITSU ML2496A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Noise Figure
Noise Figure the ratio of the signal-to-noise power ratio at the input to the signal-to-noise power ratio at the output.

Standing Wave Ratio (SWR)
Standing wave ratio (SWR) is the ratio of the amplitude of a partial standing wave at an antinode (maximum) to the amplitude at an adjacent node (minimum).


Please contact us for your ANRITSU ML2496A CALIBRATION and/or ANRITSU ML2496A 2 Channel Pulse RF Power Meter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: