ANRITSU S820D CALIBRATION and ANRITSU S820D REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANRITSU S820D Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   ANRITSU S820D   Description / Specification:    
ANRITSU S820D 20 GHz Site Master Cable and Antenna Analyzer

The Anritsu S820D Site Master is a precision hand-held return loss/SWR and fault location measurement instrument. OSL calibration can be applied to all 1-port measurements (RL/VSWR/cable Loss/DTF) enabling accurate vector corrected measurements. Site Masters' SPA has dedicated routines for one-button measurements of field strength, channel power, occupied bandwidth, adjacent channel power ratio (ACPR), Carrier-to-Interference, and interference analysis. Light weight, rugged design, and wide temperature range make them ideal for field applications. The S820D Site Master’s proprietary design provides superior immunity to on-channel RF interference, which is important for live site testing. Features. Accurate return loss/SWR and fault location measurements. Accurately tests RF transmission lines and antennas. Superior immunity to on-channel interference for testing at co-located antenna sites. Specifications. Frequency range: 25 MHz to 20 GHz. Frequency Resolution: 10 kHz. Frequency Accuracy (CW Mode): ± 3 parts per million. Display data points Selectable: 130, 259, 517. Immunity to interfering RF signals: -10 dBm (On-frequency), +13 dBm (On-channel). Return Loss Range: 0.0 to 60.00 dB, Resolution: 0.01 dB. VSWR: Range 1 to 65.53, Resolution: 0.01 dB. Cable loss: Range 0 to 30, Resolution: 0.01 dB. Distance-To-Fault (DTF) Vertical Range: Return loss, 0 to 60 dB; SWR, 1 to 65.53. DTF Horizontal range (meter): 0 to (# of data points –1) x horizontal resolution, where data points = 130, 259 or 517. Maximum Input (Damage Level) +20 dBm. Options. Option 5: Power Monitor to measure power – external detector needed. Option 31: Built-in GPS receiver provides latitude, longitude, altitude information with trace data.



 

Standard Calibration $715.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANRITSU S820D. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Adjacent Channel Power
Adjacent Channel Power is the power from a modulated communications channel that leaks into an adjacent channel. This leakage is usually specified as a ratio to the power in the main channel, but is sometimes an absolute power.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.


Please contact us for your ANRITSU S820D CALIBRATION and/or ANRITSU S820D 20 GHz Site Master Cable and Antenna Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: