FLUKE 8808A REPAIR and FLUKE 8808A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the FLUKE 8808A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 8808A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   FLUKE 8808A   Description / Specification:    
FLUKE 8808A 5 1/2 Digit Benchtop Digital Multimeter

The Fluke 8808A is a 5.5 digit portable benchtop multimeter that performs common measurements required for modern applications. It features a limit compare mode with pass/fail indicators and built-in enunciators that clearly show the operator whether a test passes or fails. It delivers a wide variety of measurement functions, including volts, ohms, and amps, plus frequency, and features a dual display that allows you to measure two different parameters of the same signal from one test connection. It also features a low-impedance operational amplifier and current-to-voltage conversion technique to eliminate burden voltage and measure sensitive low currents. Split terminal jacks for the 2x4-wire ohms function allow you to perform 4-wire measurements using only two leads instead of four.
Specifications.

Display: VFD multi segment display, dual readings.
Resolution: 5.5 digits.
DC Voltage.
  Range: 200 mV to 1000 V.
  Max. resolution: 1 uV.
  Accuracy: 0.015 + 0.003.
AC Voltage.
  Range: 200 mV to 750 V.
  Max. resolution: 1 uV.
  Accuracy: 0.2 + 0.05.
  Frequency: 20 Hz to 100 KHz.
Resistance.
  2 x 4 Wire: Yes.
  Range: 200 Ω to 100 MΩ.
  Max. resolution: 1 mΩ.
  Accuracy: 0.02 + 0.003.
DC Current.
  Range: 200 µA to 10 A.
  Max. resolution: 1 nA.
  Accuracy: 0.02 + 0.005.
AC Current.
  Range: 20 mA to 10 A.
  Max. resolution: 100 uA.
  Accuracy: 0.3 + 0.06.
  Frequency: 20 Hz to 2 kHz.
Frequency.
  Range: 20 Hz to 1 MHz.
  Max. resolution: 0.1 mHz.
  Accuracy: 0.01%.
Math functions.
  dB/dBm: Yes.
Advanced functions: Limit compare test, with pass and fail indicators.
Interfaces: RS-232, USB with optional adapter.
Programming languages/modes: Simplified ASCII, Fluke 45 remote command emulation.



 

Standard Calibration $375.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 8808A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your FLUKE 8808A REPAIR and/or FLUKE 8808A 5 1/2 Digit Benchtop Digital Multimeter CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: