EXTECH INSTRUMENTS 382152 CALIBRATION and EXTECH INSTRUMENTS 382152 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the EXTECH INSTRUMENTS 382152 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   EXTECH INSTRUMENTS 382152   Description / Specification:   Spec Sheet 
EXTECH INSTRUMENTS 382152 Earth Ground Resistance Tester

The Extech 382152 Earth Ground Resistance Tester can measure resistance (in 3 ranges) and AC voltage to 200V. 2mA constant current test signal permits earth resistance tests without tripping current breakers in the circuit under test. Single, momentary tests or automatic 3-minute tests can be selected. This device was designed to meet IEC-1010 (EN 61010) safety standards. Specifications. Measurements: Earth ground resistance (in 3 ranges) and AC voltage to 200V. Display: 3-1/2 digit (1999 count) LCD with LED test status indicator. Data hold: Freezes latest reading on the LCD display. Automatic Test: 3 minute test timer with automatic power down. Measurement triggers: Momentary test or 3 minute test with lock function. Over-range indication: '1' displayed as most significant digit. Earth Ground Resistance 2 mA test current (820 Hz) Range: 20, 200, 2000 ohm. Resolution: 0.01, 0.1, 1 ohm. Accuracy: ± (2% rdg + 2 d) or ± 0.1 ohm whichever is greater. Earth Voltage Frequency: 40 to 500 Hz Range: 0 to 200 VAC. Resolution: 0.1V. Accuracy: ± (1% rdg +2d).



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the EXTECH INSTRUMENTS 382152. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bandwidth
Bandwidth is the difference between the upper and lower frequencies in a contiguous set of frequencies within which a component, link or network will operate.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Noise Figure
Noise Figure the ratio of the signal-to-noise power ratio at the input to the signal-to-noise power ratio at the output.

Ringing
Ringing is an unwanted oscillation of a voltage or current.


Please contact us for your EXTECH INSTRUMENTS 382152 CALIBRATION and/or EXTECH INSTRUMENTS 382152 Earth Ground Resistance Tester REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: