EXFO FLS-5834A REPAIR and EXFO FLS-5834A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the EXFO FLS-5834A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the EXFO FLS-5834A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Laser Source (DFB-LD-WDM-BBS)?
Shop for Comparable Products on our
 used Laser Source (DFB-LD-WDM-BBS) page or new Laser Source (DFB-LD-WDM-BBS) page

 
   EXFO FLS-5834A   Description / Specification:    
EXFO FLS-5834A CD/PMD Analyzer Source

The Exfo FLS-5834A CD/PMD Analyzer Source provides high-power super LED (SLED), modulated for chromatic dispersion measurement, Polarized for PMD measurement and offers a broadband spectral range. The FLS-5834A’s high modulation makes it a perfect complement to the FTB-5800 Chromatic Dispersion Analyzer, whose technology is based on the phase-shift method. This first-class duo lets you run chromatic dispersion (CD) measurements through amplifiers such as EDFAs, providing the highest accuracy in field CD testing. When you need a broadband, highly polarized source for measuring PMD, turn to the FLS-5834A. Test PMD through EDFAs by combining the FLS-5834A with the patent-design breakthrough technology of the FTB-5500B PMD Analyzer. Center wavelength (nm): 1580 ±20. Output power (dBm): 7. Peak spectral density (dBm/nm): >-12.5. Power stability (15 minutes) (dB): < 0.075. Modulation frequency (MHz): 100. Temperature operating: 0 °C to 40 °C (32 °F to 104 °F); storing -20 °C to 50 °C (-4 °F to 122 °F). Relative humidity (non-condensing): 0 % to 90 %, Size (H x W x D): 117mm x 222 mm x 333 mm (4 5/8 in x 8 3/4 in x 13 1/8 in). Weight (without transceivers): 3.2 kg (7.1 lb).



 

Standard Calibration $550.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the EXFO FLS-5834A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bit Error Ratio (BER)
Bit Error Ratio (BER) is the ratio of errors caused by the number of bits in a data stream that have been altered due to noise, interference, distoriton or bit synchronization errors.

Flatness
Variation of insertion loss on the passband of an optical device.

Polarization Dependent Loss (PDL)
Polarization Dependent Loss is the difference between the maximum and minimum values of loss due to the variation of the polarization states of light propagating through a device. PDL is expressed in decibels. Calculated by; PDL = 10 log10 (Ep/Es), where EP and ES are the measured diffraction efficiencies for P- and S-plane polarized incident light, respectively.

Return Loss (RL)
Return Loss (RL) is the ratio of the incident power to the reflected power expressed in dB. RL = 10log (Pin/Pback)

Wavelength Resolution
Wavelength Resolution is the smallest possible displayed wavelength increment/decrement.


Please contact us for your EXFO FLS-5834A REPAIR and/or EXFO FLS-5834A CD/PMD Analyzer Source CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: