TEKTRONIX TDS6154C CALIBRATION and TEKTRONIX TDS6154C REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX TDS6154C Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   TEKTRONIX TDS6154C   Description / Specification:    
TEKTRONIX TDS6154C 4 Ch 15 GHz Digital Storage Oscilloscope

The Tektronix TDS6154C 15 GHz 4 channel Digital Storage Oscilloscope provides acquisition architecture with 40 GS/s maximum sample rate and 64 Megasamples record length on two channels (20 GS/s and 32 Megasamples on each of the four channels simultaneously), for the acquisition power you need. It provides the ultimate combination of bandwidth, sample rate, and record length for the fastest signals. The TDS6154C provides matched 15 GHz performance across any two channels using advanced, Tektronix-proprietary DSP enhancement, important for high-speed channel-channel measurements. The user-selectable DSP filter on each channel provides magnitude and phase correction, plus extension of the analog bandwidth to 15 GHz for more accurate signal fidelity on high-speed measurements – easily capturing the fifth harmonic of 3.0 GHz embedded clocks used in next-generation 6.0 Gb/s serial data standards, and even the third harmonic of 5 GHz clocks being developed for future systems. The DSP filter on each channel can also be switched off to take advantage of true 12 GHz analog bandwidth for applications needing the highest available raw data capture. Specifications. Bandwidth, Rise Time (DSP): 15 GHz, 28 ps (10-90%) (typical). True Analog Bandwidth (-3 dB), typical Rise Time: 12 GHz, 35 ps (10-90%) (typical). Hardware Bandwidth Limits (Requires TCA-1MEG Adapter): Full, 250 MHz, or 20 MHz. Input Coupling: DC, GND. Input Impedance: 50 ohm ±2%. Vertical Resolution: 8 bit (>11 bit with averaging). Max Input Voltage, 50 ohm: <1 VRMS for <1 V full-scale, <5.5 V for >=1 V full-scale. DC Gain Accuracy: ±2%. Timebase System. Timebase Range: 25 ps to 40 s/div; Interpolation down to 500 fs/pt. Timebase Delay Time Range: 5 ns to 250 s. Channel-to-Channel Deskew Range: ±75 ns. Trigger Jitter (RMS): <1 psRMS (typical). Clock Stability: <1 ppm (typical), <2.5 ppm (guaranteed) Acquisition System. Max Sample Rate: 40 GS/s on 2 channels, 20 GS/s on 4 channels. Equivalent Time Sample Rate (max): 2 TS/s. Maximum Record Length per Channel: 4 M on two channels; 2 M on all 4 channels, (64 M on two channels; 32 M on all 4 channels (requires Opt. 4M)). Maximum Time Duration Captured at Highest Real-time Resolution (two Channels): 100 µs (Standard Memory). Options. Opt. 2M – 16 MSamples on two channels; 8 MSamples on all channels. Opt. 3M – 32 MSamples on two channels; 16 MSamples on all channels. Opt. 4M – 64 MSamples on two channels; 32 MSamples on all channels. Opt. CP2 – TDSCPM2 ANSI/ITU Telecom Pulse Compliance Testing Software (requires Opt. SM). Opt. DVI – TDSDVI DVI Compliance Test Solution. Opt. ET3 – TDSET3 Ethernet Compliance Test Software. Opt. HT3 – HDMI Compliance Test Software. Opt. JA3 – TDSJIT3 v2.0 Advanced Jitter Analysis Software. Opt. JE3 – TDSJIT3 v2.0 Essentials Jitter Analysis Software. Opt. J2 – TDSDDM2 Disk Drive Analysis Software. Opt. PW3 – TDSPWR3 Power Measurement and Analysis Software. Opt. RTE – TDSRT-Eye™ Serial data compliance and analysis software. Opt. RJA – Software Bundle of TDSJIT3 v2.0 (Opt. J3A), TDSRT-Eye (Opt. RTE), and Protocol Trigger Decode (Opt. PTD). Opt. RSA – Software Bundle of TDSJIT3 v2.0 (Opt. J3A), RT-Eye (Opt. RTE), Serial Trigger (Opt. ST), Protocol Trigger and Decode (Opt. PTD), and Serial Mask testing (Opt. SM). Opt. PCE – PCI Express™ Compliance Module for Opt. RTE. Opt. PTD – Protocol Trigger and Decode (provides protocol decode on all models, requires Opt. ST for protocol triggering on the TDS6000C Series only). Opt. IBA*9 – InfiniBand® Compliance Module for Opt. RTE. Opt. SM – Serial Communications Mask Testing (enables hardware clock recovery). Opt. SST – SATA and SAS Analysis Software Module for Opt. RTE. Opt. ST – Serial Pattern Trigger (enables hardware clock recovery). Opt. USB – TDSUSBS USB 2.0 Compliance Test SW Only.



 

Standard Calibration $475.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX TDS6154C. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your TEKTRONIX TDS6154C CALIBRATION and/or TEKTRONIX TDS6154C 4 Ch 15 GHz Digital Storage Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: