YOKOGAWA 7556-755611 CALIBRATION and YOKOGAWA 7556-755611 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA 7556-755611 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another General Meter?
Shop for Comparable Products on our
 used General Meter page

 
   YOKOGAWA 7556-755611   Description / Specification:    
YOKOGAWA 7556-755611 Digital Resistance Meter

Yokogawa 7556 High-speed Resistance Meter for Production Line of Fixed Chip Resistors. High-speed measurement (2.8 ms). Highly accurate ±(0.006% of reading + 3 digits in 755611). High resolution (5.5 digits in 755611). Wide range (1 ohm range to 100 M-ohm range). Full remote control through serial (RS-232) or GP-IB interface. Software-based calibration function. Printer output of measurement results and statistics. Advanced contact check function. Specifications. Range: 1 ohm, 10 ohm, 100 ohm, 1 k-ohm, 10 k-ohm, 100 k-ohm, 1 M-ohm, 10 M-ohm, 100 M-ohm. Absolute value display: 10 µ ohm (at 1 ohm range). Measurement time Fast mode: 5.7 ms. Measurement time High speed mode: 2.8 ms. Accuracy (at 1 k-ohm range, 23 ±5°C, normal mode): ±(0.006% of reading + 3digits). Contact check function; Check level: 1 ohm to 30 ohm (selectable). Execute checks before or after a measurement (selectable). Check current: 50 mA. Contact check error message with display and handler interface. Measured current abnormality message with display and handler interface. Comparator function (both Hi and Lo). Deviation setting range: -9.999% to 9.999%/ -99.99% to 99.99% (selectable). Absolute value setting range: 0.0000 ohm to 1.2000 ohm. Data memory: Max. 2000 data.



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA 7556-755611. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your YOKOGAWA 7556-755611 CALIBRATION and/or YOKOGAWA 7556-755611 Digital Resistance Meter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: