YOKOGAWA DL1540C-701530 CALIBRATION and YOKOGAWA DL1540C-701530 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA DL1540C-701530 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   YOKOGAWA DL1540C-701530   Description / Specification:    
YOKOGAWA DL1540C-701530 4 Ch 150 MHz Digital Oscilloscope

The Yokogawa DL1540C-701530 is a Digital Oscilloscope. DC to 150 MHz Bandwidth, No. of input channels: 4 (CH1 to CH4), analog input. Input coupling: AC, DC, GND. Input connector: BNC connector. Input impedance: 1 M ohm ±1.5% (approx. 25 pF). Maximum input voltage: 250 V(DC+ACpeak) or 177 Vrms. Trigger Sensitivity: 1 div p-p (DC to 150 MHz). Voltage axis sensitivity setting range 1 mV/div to 5 V/div (in multiples of 1, 2 and 5). Time axis setting range 5 ns/div to 50 s/div. Time axis accuracy ± (0.01 % + 500 ps). Maximum Record length: 2 channels measurement ; 120 K (100 K)W/CH (for CH1/CH2 only), 3/4 channels measurement : 56 K (50 K)W/CH. Max sampling rate: 2 channels measurement ; 200 MS/s (CH1/CH2), 3/4 channels measurement ; 100 MS/s. Display Size: 6.4, colored TFT LCD, display resolution: 640 dots x 480 dots. RS-232-C interface, GP-IB interface.



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA DL1540C-701530. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your YOKOGAWA DL1540C-701530 CALIBRATION and/or YOKOGAWA DL1540C-701530 4 Ch 150 MHz Digital Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: