YOKOGAWA DL716-701830 CALIBRATION and YOKOGAWA DL716-701830 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA DL716-701830 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   YOKOGAWA DL716-701830   Description / Specification:    
YOKOGAWA DL716-701830 Digital Oscilloscope Mainframe

The Yokogawa DL716-701830 Digital Oscilloscope Mainframe is designed for measuring multi-channel isolated physical signals. The modular inputs provide flexibility for various applications. The DL716-701830 provides data acquisition and recording technology to measure signals ranging from slow changing temperature to high-speed MHz signals. One instrument will provide a wide range of measurements. Features up to 16 channels, isolated inputs. Horizontal Max. record length (using four channels): 1 M word (standard), 8 M words (with /M1 option), 32 M words (with /M2 option), 64 M words (with /M3 option). Sweep time: 100k words/ch model: 500 ns/div to 50000 s/div (1-2-5 steps), Other models: 500 ns/div to 100000 s/div (1-2-5 steps). 10 MS/s max. sampling rate, 10 bits 16 M words (with high-speed module). 100 kS/s max. sampling rate, 16 bits, 16 M words (with high-resolution module). Display: 10.4-inch TFT color liquid crystal display. RS-232-C interface, GP-IB interface. Power supply: 100 to 120/200 to 240 V AC, automatic switching. Plug-in modules. 701855, High-speed isolation module (12-bit A/D resolution). 701856, High-speed module (12-bit A/D resolution). 701852, High-resolution, high-voltage isolation module. 701853, High-resolution isolation module. 701857, High-resolution voltage/RMS isolation module. 701860, Temperature module. 701870, Logic input module. 701880, Strain module. 701885, Strain module (with shunt Cal). Options. M1, Memory expansion to 2MW/ch. M2, Memory expansion to 8MW/ch. M3, Memory expansion to 16MW/ch.



 

Standard Calibration $220.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA DL716-701830. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your YOKOGAWA DL716-701830 CALIBRATION and/or YOKOGAWA DL716-701830 Digital Oscilloscope Mainframe REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: