YOKOGAWA DL7200-701440 CALIBRATION and YOKOGAWA DL7200-701440 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA DL7200-701440 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   YOKOGAWA DL7200-701440   Description / Specification:    
YOKOGAWA DL7200-701440 4 Ch 500 MHz SignalExplorer Digital Oscilloscope

The Yokogawa DL7200-701440 SignalExplorer was designed to satisfy the key feature requirements for waveform measuring systems. These features are: Simple and accurate capturing of complex signals. High-speed extraction and screen display of desired information from large volumes of captured data. Specifications. DC to 500 MHz Bandwidth. Input channels: 4 analog (CH1 through CH4) and 16-bit digital (optional). Input impedance: 1 M-ohm ±1.0%, approx. 20 pF, 50 ohm ±1.0% (V SWR 1.4 or less (DC to 500 MHz)). Voltage-axis sensitivity setting: 1 M-ohm input : 2 mV/div to 10 V/div (1 - 2 - 5 steps), 50 ohm input : 2 mV/div to 1 V/div (1 - 2 - 5 steps). Time axis range: 1 ns/div to 50 s/div (record length is 10 k Words or more), 1 ns/div to 5 s/div (record length is 1 k Words). Time base precision: ±(0.005%). Maximum sample rate Realtime sampling mode: With interleave ON : 2 GS/s, With interleave OFF : 1 GS/s. Maximum record length: With interleave ON : 16 MWords/CH, With interleave OFF: 8 MWords/CH. Display 8.4 - inch (approx. 21.3 cm) color TFT liquid crystal display.



 

Standard Calibration $330.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA DL7200-701440. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your YOKOGAWA DL7200-701440 CALIBRATION and/or YOKOGAWA DL7200-701440 4 Ch 500 MHz SignalExplorer Digital Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: