YOKOGAWA SL1000-720120 CALIBRATION and YOKOGAWA SL1000-720120 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA SL1000-720120 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Data Acquisition?
Shop for Comparable Products on our
 used Data Acquisition page

 
   YOKOGAWA SL1000-720120   Description / Specification:    
YOKOGAWA SL1000-720120 High Speed Data Acquisition Mainframe Unit

The Yokogawa SL1000-720120 High Speed Data Acquisition Mainframe Unit delivers independent, isolated channel hardware at 100MS/ch rates, with no compromise in bit resolution, memory depth, or streaming performance. Features. Up to 100 MS/s on all channels (10 ns sampling interval). New 100 MS/s 12-Bit 1 kV¹ isolation module with 20 MHz bandwidth. Supports parallel testing: Perform measurements with up to four simultaneously independent sample rates. Stream data to PC via high speed USB 2.0 or 1000BASE-T Gigabit Ethernet. Real time display on a PC (GIGAZoom engine). Stream data to a PC hard disk or the SL1000's internal hard disk² in real time (at speeds of 1.6 MS/s = 100 kS/s x 16ch). Plug & Play: Auto-recognition of units and modules. Input type: Plug-in module (A/D converters built in to each unit). Maximum number of input channels: 16 (One unit operation), 128 (8 units synchronous operation). Maximum sample rate: 100 MS/s on all channels. Plug-in Modules. 720210, High-speed 100MS/s 12-Bit Isolation Module (2ch). 701250, High-speed 10MS/s 12-Bit Isolation Module (2ch). 701251, High-speed 1MS/s 16-Bit Isolation Module (2ch). 701255, High-speed 10MS/s 12-Bit non-Isolation Module (2ch). 701260, High-voltage 100kS/s 16-Bit Isolation Module (with RMS, 2ch). 701261, Universal Module (2ch). 701262, Universal Module (with Anti-Aliasing Fileter, 2ch). 701265, Temparature / High-precision voltage Module (2ch). 701275, Acceleration / Volatage Module (with Anti-Aliasing Filter 2ch). 701270, Strain Module (NDIS, 2ch). 701271, Strain Module (DSUB, Shunt-CAL, 2ch). 701280, Frequency Module. Options. HD1, Internal 40 GB HDD. C10, Ethernet Interface. P4, Probe power (4-output).



 

Standard Calibration $255.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA SL1000-720120. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your YOKOGAWA SL1000-720120 CALIBRATION and/or YOKOGAWA SL1000-720120 High Speed Data Acquisition Mainframe Unit REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: