YOKOGAWA SL1400-701240 CALIBRATION and YOKOGAWA SL1400-701240 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA SL1400-701240 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Data Acquisition?
Shop for Comparable Products on our
 used Data Acquisition page

 
   YOKOGAWA SL1400-701240   Description / Specification:    
YOKOGAWA SL1400-701240 ScopeCorder LITE Mainframe

The Yokogawa SL1400-701240 ScopeCorder LITE Mainframe is a plug-in module type chart recorder with a large built-in A4 sized high resolution thermal printer. It provides more simplified and intuitive, easy-to-use operational functions. Features. Number of Slots 8 (up to 16 channels). Maximum sampling rate: 10 MS/s (module dependent). Logic inputs: 16 (8 bits x 2). Max. record length: Standard 2.5 MW/CH, 50 MW total. Time axis accuracy: ±0.005%. Time axis setting range: 100 µsec to 5 sec (in steps of 1, 2, or 5); 10 sec to 60 min (in steps of 1-2-3-5-6); 100 min/120 min/300 min; 10 h/20 h/30 h/50 h/100 h/120 h; 10 days/20 days/30 days. Acquisition modes Normal, Envelope, Averaging, Box average. Display: 10.4-inch color TFT liquid crystal display (SVGA 800 x 600 dots). Built-in printer, A4 size (210 mm wide x 20 m). Plug-in Modules. 701250, High-speed 10MS/s 12-Bit Isolation Module (2ch). 701251, High-speed 1MS/s 16-Bit Isolation Module (2ch). 701255, High-speed 10MS/s 12-Bit non-Isolation Module (2ch). 701260, High-voltage 100kS/s 16-Bit Isolation Module (with RMS, 2ch). 701261, Universal Module (2ch). 701262, Universal Module (with Anti-Aliasing Fileter, 2ch). 701265, Temparature / High-precision voltage Module (2ch). 701275, Acceleration / Volatage Module (with Anti-Aliasing Filter 2ch). 701270, Strain Module (NDIS, 2ch). 701271, Strain Module (DSUB, Shunt-CAL, 2ch). 701280, Frequency Module. Options. C8, Internal 40 GB HDD. C10, Ethernet Interface. P4, Probe power (4-output).



 

Standard Calibration $95.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA SL1400-701240. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your YOKOGAWA SL1400-701240 CALIBRATION and/or YOKOGAWA SL1400-701240 ScopeCorder LITE Mainframe REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: