KEITHLEY 2636A CALIBRATION and KEITHLEY 2636A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the KEITHLEY 2636A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another General Meter?
Shop for Comparable Products on our
 used General Meter page

 
   KEITHLEY 2636A   Description / Specification:   Spec Sheet 
KEITHLEY 2636A Dual-Channel System Source Meter

Dual-channel System SourceMeter Instrument. Combines a precision power supply, true current source, DMM (DCV, DCI, ohms, and power with 5½-digit resolution), arbitrary waveform generator, V or I pulse generator with measurement, electronic load (with sink mode capability), and trigger controller in one instrument. Current arbitrary waveforms maximum output update rates: 12,500 samples/second. Voltage arbitrary waveforms maximum output update rates: 20,000 samples/second. Voltage source range 200.000 mV (5 µV) to 200.000 V (5 mV). Current source range 1.000 nA (20 fA) to 10.000 A (200 µA), 10A range accessible only in pulse mode.



 

Standard Calibration $605.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the KEITHLEY 2636A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your KEITHLEY 2636A CALIBRATION and/or KEITHLEY 2636A Dual-Channel System Source Meter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: