FLUKE I30 CALIBRATION and FLUKE I30 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE I30 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   FLUKE I30   Description / Specification:    
FLUKE I30 30 Amp True RMS AC/DC Mini Clamp

The Fluke i30 current clamp is based on Hall Effect technology for use in measurement of both DC and AC current. The i30 may be used in conjunction with multimeters, recorders and other suitable recording instruments for accurate non-intrusive current measurement. It has current ranges from 30 mA to 30 A DC, 30 mA to 20 A AC rms and a frequency range from DC to 20 kHz (-0.5 dB). It also has a CAT III 300 V safety rating.
Specifications.

Specified current range: 30 mA to 30 A DC, 30 mA to 20 A AC rms.
Usable current range: 5 mA to 30 A DC, 30 mA to 20 A AC rms.
Crest Factor: 1.4 in.
Output sensitivity: 100 mV/A.
Accuracy (at +25°C).
  DC ±1 % of reading ±2 mA.
  AC ± 0.5 dB of reading ±2 mA.
Resolution: ±1 mA.
Load impedance: > 10 k Ohms and ≤ 100pF.
Conductor position sensitivity: ±1% relative to center reading.
Frequency range: DC to 20 kHz (-0.5 dB).
Temperature coefficient: ±0.01% of reading/°C.
Working voltage: 300 V AC rms or DC.
Maximum conductor size: 19 mm diameter.
Output connection: 4 mm safety connector.
Output zero: Manual adjust via thumbwheel.
Cable length: 1.5 meters.



 

Standard Calibration $260.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE I30. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your FLUKE I30 CALIBRATION and/or FLUKE I30 30 Amp True RMS AC/DC Mini Clamp REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: