ILX LIGHTWAVE TCM-39034 CALIBRATION and ILX LIGHTWAVE TCM-39034 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ILX LIGHTWAVE TCM-39034 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Laser Diode Controller?
Shop for Comparable Products on our
 used Laser Diode Controller page

 
   ILX LIGHTWAVE TCM-39034 (39034)   Description / Specification:    
ILX LIGHTWAVE TCM-39034 32W TEC Module with Voltage Measurement

The ILX Lightwave TCM-39034 TEC module controls temperature of devices with 32W of power with Voltage Measurement. This TEC module offers maximum flexibility with a choice of operating modes and temperature sensors covering thermistors, IC, and RTDs. A low noise, bipolar output with TE voltage measurement and an ultra-stable topology achieves stabilities better than 0.005°C. A smart integrator control loop, programmable from the front panel or through GPIB, delivers fast settling times.
Specifications.

Temperature Control Output.
Temperature Control Range: -99 to 199.9° C.
Temperature Setpoint Resolution: 0.1° C (-20°C to 20°C), 0.2° C (20°C to 50°C).
Temperature Setpoint Accuracy: ±0.2° C.
Short-Term Stability (1 hr): ±0.004° C.
Long-Term Stability (24 hr): ±0.01° C.

TEC Output.
Type: Bipolar current source.
Isolation: Isolated from other modules and earth ground.
Control Algorithm Smart Integrator, Hybrid PI.
Compliance Voltage: >8 V.
Short Circuit Output Current: 4A.
Maximum Output Power: 32W.
Current Noise and Ripple: <1 mA rms.



 



Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Coherence Length
Average distance over which superimposed waves lose their phase relationships

Linewidth
Linewidth is the width of a spectral line in terms of wavelength, wave number and frequency.

Power Flatness Versus Wavelength
When changing the wavelength at constant power setting and recording the differences between actual and displayed power levels, the power flatness is ± half the span (in dB) between the maximum and the minimum of the measured power levels.

Spectral Width
Spectral Width is the wavelength interval over which the magnitude of all spectral components is equal to or greater than a specified fraction of the magnitude of the component having the maximum value. In optical communications applications, the usual method of specifying spectral width is the full width at half maximum. This is the same convention used in bandwidth, defined as the frequency range where power drops by less than half (at most -3 dB).

Telecom Bands
Optical fiber communications typically operate in a wavelength region corresponding to one of the following Bands. O Band (original): 1260–1360 nm. E Band (extended): 1360–1460 nm. S Band (short wavelengths): 1460–1530 nm. C Band (conventional): 1530–1565 nm. L Band (long wavelengths): 1565–1625 nm. U Band (ultralong wavelengths): 1625–1675 nm


Please contact us for your ILX LIGHTWAVE TCM-39034 CALIBRATION and/or ILX LIGHTWAVE TCM-39034 32W TEC Module with Voltage Measurement REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: