DATRON 4800 REPAIR and DATRON 4800 CALIBRATION

 
Custom-Cal has a high success rate in the repair of the DATRON 4800. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the DATRON 4800 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Calibrator?
Shop for Comparable Products on our
 used Calibrator page

 
   DATRON 4800   Description / Specification:    
DATRON 4800 Multifunction DMM Calibrator

The Datron 4800 Multifunction DMM Calibrator is designed to be supported by the 4950 Multifunction Transfer Standard. DC Voltage (Option 10); Ranges: 100 uV to 1000V in decades. Resolution: 7 1/2 digits or 10 nV, whichever is greater. Output Impedance/Max Output Current: 100 uV to 100 mV Ranges, 100 ohm. 1V to 1000V Ranges, 25 mA max. AC Voltage (Option 20); Ranges: 1 mV to 1000V in decades. Resolution: 6 1/2 digits or 100 nV, whichever is greater. Frequency: Ranges: 10 Hz to 1 MHz. Resolution: 1% of setting or 1Hz. Accuracy: <±100 ppm. Maximum Capacitive load: 1000 pF on 1V to 100V ranges, 300 pF on 1000V range. DC Current (Option 40); Ranges: 100 uA to 10A in decades. Resolution: 6 1/2 digits or 100 pA, whichever is greater. AC Current (Option 40); Ranges: 100 mA to 10A in decades. Resolution: 6 1/2 digits or 100 pA. whichever is greater. Resistance (Option 50); Ranges: 10 ohms to 100 Mohm in decades. (Ranges are nominal, actual calibrated values are displayed). Connections: Selectable 2 or 4-wire, remote/local guard. Display Resolution: 7 1/2 digits. IEEE-488 interface. OPTIONS; 10: DCV Ranges to 200V. 20: ACV Ranges to 200V. 30: 1000V range for DCV, ACV (requires option 10, option 20 or both). 40: DCI and ACI to 2A (requires option 10, option 20 or both). 50: Ohm Ranges. 60: DCI and ACI ranges extender to 11A DC or RMS AC (requires Options 10 and/or 20 and option 40).



 

Standard Cal with Data $1,305.00 *
*This is a Web introductory price for one calibration of the DATRON 4800. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your DATRON 4800 REPAIR and/or DATRON 4800 Multifunction DMM Calibrator CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: