KEITHLEY 2308 REPAIR and KEITHLEY 2308 CALIBRATION

 
Custom-Cal has a high success rate in the repair of the KEITHLEY 2308. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the KEITHLEY 2308 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   KEITHLEY 2308   Description / Specification:    
KEITHLEY 2308 Portable Device Battery/Charger Simulator

The Keithley 2308 Portable Device Battery/Charger Simulator is a specialized dual-channel power supply for design and testing of portable, battery-operated devices. Ultra-fast response to pulsed load operation. Speed-optimized command set reduces test times. Variable output resistance for simulating an actual battery's output response. Simulate a discharged battery and test charge control circuit performance with both a battery supply that can sink up to 3A and a charger supply. Pulse peak, average, and baseline current measurements. Integrating A/D converter for more precise measurements. 100nA current measurement sensitivity. Analog output for complete load current waveform characterization. Catch production wiring problems immediately with open sense-lead detection Built-in digital voltmeter. Four built-in digital control lines. Specifications. Output #1 (Battery Channel): Output Voltage: 0 to +15VDC. Output Accuracy: (0.05% + 3mV). Programming Resolution: 1mV. Readback Accuracy: ±(0.05% + 3mV). Readback Resolution: 1mV. Stability: 0.01% + 0.5mV. DC Current Source Compliance Accuracy: ±(0.16% + 5mA). Programmed Source Compliance Resolution: ±1.25mA. Stability: 0.01% + 50µA. Output #2 (Charger Channel): Output Voltage: 0 to +15VDC. Output Accuracy: ±(0.05% + 10mV). Programming Resolution: 10mV. Readback Accuracy: ±(0.05% + 3mV). Readback Resolution: 1mV. DC Current Source Compliance Accuracy: ±(0.16% + 5mA). Programmed Source Compliance Resolution: ±1.25mA. Stability: 0.01% + 50µA.



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the KEITHLEY 2308. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your KEITHLEY 2308 REPAIR and/or KEITHLEY 2308 Portable Device Battery/Charger Simulator CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: