NEWPORT 8601.8C CALIBRATION and NEWPORT 8601.8C REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the NEWPORT 8601.8C Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Laser Diode Controller?
Shop for Comparable Products on our
 used Laser Diode Controller page

 
   NEWPORT 8601.8C   Description / Specification:    
NEWPORT 8601.8C Combination LDD/TEC Module

The Newport 8601.8C is a 100 mA 2A/4V Combination LDD/TEC Module. Specifications. Laser Output; Output Current Range: 0 to 100 mA. Output Current Resolution (16-bit): 0.0015 mA. Output Current Accuracy: 0.03 + 5 µA. Compliance Voltage: 3 Volts. Temperature Coefficient (Full Scale): < 50 ppm/°C. Short Term Stability (1 hr., Full Scale): < 10 ppm. Long Term Stability (24 hr., Full Scale): < 50 ppm. Noise/Ripple (rms): < 2 µA. Current Limit; Range: 0 to 100 mA. Resolution: 1 mA. Accuracy: ± 2 mA. Internal Function Generator; Waveforms: Sine & square wave. Frequency Range 1: 200 Hz to 2 kHz. Frequency Range 2: 2 kHz to 300 kHz. Squarewave Duty Cycle (± 5%): 50%. Frequency Accuracy: ± 5 %. Amplitude Accuracy: ± 5 %. Sinewave Total Harmonic Distortion: < 2 %. Squarewave risetime: < 500 ns. Photodiode Input; Range: 0 - 5 mA. Stability (Full Scale, 24 hours): ± 0.02 %. Accuracy: 0.004 + 0.5 µA. Measurement Display; Output Current Range: 0 to 100.00 mA. Output Current Resolution: 0.01 mA. Output Current Accuracy: 0.02 + 10 µA. Forward Voltage Range: 0.000 to 3.000 Volts. Forward Voltage Resolution: 0.1 mV. Forward Voltage Accuracy: 0.005 + 0.3 mV. Photodiode Current Range: 5 - 5,000 µA. Photodiode Current Resolution: 0.1 µA. Photodiode Current Accuracy: 0.01 + 0.5 µA. PD Resp. Range (µA/mW): 0.00 to 600.00. PD Resp. Resolution (µA/mW): 0.01. Optical Power Range: 0.00 to 100.00 mW. Optical Power Resolution: 0.01 mW. TEC Output; Maximum Current: 2 Amps. Maximum Voltage: 4 Volts. Typical Power: 8 Watts. Current Limit; Range: 0 to 2 Amps. Accuracy: ± 10 mA.



 

Standard Calibration $95.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the NEWPORT 8601.8C. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Coherence Length
Average distance over which superimposed waves lose their phase relationships

Linewidth
Linewidth is the width of a spectral line in terms of wavelength, wave number and frequency.

Power Flatness Versus Wavelength
When changing the wavelength at constant power setting and recording the differences between actual and displayed power levels, the power flatness is ± half the span (in dB) between the maximum and the minimum of the measured power levels.

Spectral Width
Spectral Width is the wavelength interval over which the magnitude of all spectral components is equal to or greater than a specified fraction of the magnitude of the component having the maximum value. In optical communications applications, the usual method of specifying spectral width is the full width at half maximum. This is the same convention used in bandwidth, defined as the frequency range where power drops by less than half (at most -3 dB).

Telecom Bands
Optical fiber communications typically operate in a wavelength region corresponding to one of the following Bands. O Band (original): 1260–1360 nm. E Band (extended): 1360–1460 nm. S Band (short wavelengths): 1460–1530 nm. C Band (conventional): 1530–1565 nm. L Band (long wavelengths): 1565–1625 nm. U Band (ultralong wavelengths): 1625–1675 nm


Please contact us for your NEWPORT 8601.8C CALIBRATION and/or NEWPORT 8601.8C Combination LDD/TEC Module REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*