NEW JGR MBR5-24 SALES and JGR MBR5-24 CALIBRATION

 
Custom-Cal has for sale a new JGR MBR5-24. Also, short calibration turn times minimize downtime and reasonable rates decrease your long-term cost of ownership and minimizes downtime of the JGR MBR5-24. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Back Reflection Meter? Shop for Comparable Products on our   new Back Reflection Meter page

 
   JGR MBR5-24   Description / Specification:    
JGR MBR5-24 24-Ch Backreflection Meter

The JGR MBR5-24 Twenty-Four Channel Multi-Output Backreflection Meter series is an instrument developed with extremely stable optics for precise measurement of backreflection, insertion loss and power. It has twenty-four output channels, the MBR5-24 is a practical choice for both single fiber and ribbon fiber testing. The MBR5-24 features up to twelve built-in laser sources at wavelengths of 850, 1310, 1490, 1550, 1625 and 1650 nm (depending on fiber type), and can be configured for single-mode or multimode measurement. An intuitive display and keypad simplifies the collection and management of measurement data allowing quick access to the test results from various channels. The meter may be controlled through remote interface (GPIB, RS232, or USB*) or locally via the user-friendly front panel keypad and display. The MBR5 achieves ultra-stable backreflection measurements at very low values. Accuracy is typically ±0.4 dB and measurement sensitivity is to -80 dB. Insertion loss relative accuracy is ±0.05 dB. In addition, the cavity option is particularly useful for ribbon connectors with large fiber counts. The MBR5 and GMS Software can be used with the SX8 switch. All our MBR5 meters come standard with our GMS Software. Specifications. Fiber Type: 9/125(SM), 50/125 or 62.5/125 (MM). Operating Wavelengths: 1310 / 1490 / 1550 / 1625 / 1650 nm (SM), 850 / 1310 nm (MM). Backreflection Range: 0 to -80 dB (SM), 0 to -60 dB (MM). Backreflection Accuracy: ± 0.4. Detector Type: 2mm InGaAs / 5mm Ge / Cavity. Power Range: 0 to -80 dBm, 0 to -60 dBm, 0 to -40 dBm. Absolute Power Accuracy: ± 0.25 dB. Relative Power Accuracy: ± 0.05 dB (< 5 dB loss), ± 0.15 dB (> 5 dB loss). Remote Interface: GPIB, RS232, USB. Display: 16 character per line LCD. Common configurations. MBR5-24-3050-C-09FA, MBR5-24-3450-C-09FA, MBR5-24-3456-C-09FA, MBR5-24-8300-C-50FA and BR5-24-8300-C-62FA.


Additional Repair Services / Information.


JGR MBR5-24 Configurations
Single Mode Configurations:
MBR5-24-0006-2-09FA: one 1625 nm laser, 2 mm InGaAs detector
MBR5-24-0007-2-09FA: one 1650 nm laser, 2 mm InGaAs detector
MBR5-24-0050-2-09FA: one 1550 nm laser, 2 mm InGaAs detector
MBR5-24-0056-2-09FA: one 1550 nm laser, one 1625 nm laser, 2 mm InGaAs detector
MBR5-24-0057-2-09FA: one 1550 nm laser, one 1650 nm laser, 2 mm InGaAs detector
MBR5-24-0400-2-09FA: one 1490 nm laser, 2 mm InGaAs detector
MBR5-24-0406-2-09FA: one 1490 nm laser, one 1625 nm laser, 2 mm InGaAs detector
MBR5-24-0407-2-09FA: one 1490 nm laser, one 1650 nm laser, 2 mm InGaAs detector
MBR5-24-0450-2-09FA: one 1490 nm laser, one 1550 nm laser, 2 mm InGaAs detector
MBR5-24-0456-2-09FA: one 1490 nm laser, one 1550 nm laser, one 1625 nm laser, 2 mm InGaAs detector
MBR5-24-0457-2-09FA: one 1490 nm laser, one 1550 nm laser, one 1650 nm laser, 2 mm InGaAs detector
MBR5-24-3000-2-09FA: one 1310 nm laser, 2 mm InGaAs detector
MBR5-24-3006-2-09FA: one 1310 nm laser, one 1625 nm laser, 2 mm InGaAs detector
MBR5-24-3007-2-09FA: one 1310 nm laser, one 1650 nm laser, 2 mm InGaAs detector
MBR5-24-3050-2-09FA: one 1310 nm laser, one 1550 nm laser, 2 mm InGaAs detector
MBR5-24-3056-2-09FA: one 1310 nm laser, one 1550 nm laser, one 1625 nm laser, 2 mm InGaAs detector
MBR5-24-3057-2-09FA: one 1310 nm laser, one 1550 nm laser, one 1650 nm laser, 2 mm InGaAs detector
MBR5-24-3400-2-09FA: one 1310 nm laser, one 1490 nm laser, 2 mm InGaAs detector
MBR5-24-3406-2-09FA: one 1310 nm laser, one 1490 nm laser, one 1625 nm laser, 2 mm InGaAs detector
MBR5-24-3407-2-09FA: one 1310 nm laser, one 1490 nm laser, one 1650 nm laser, 2 mm InGaAs detector
MBR5-24-3450-2-09FA: one 1310 nm laser, one 1490 nm laser, one 1550 nm laser, 2 mm InGaAs detector
MBR5-24-3456-2-09FA: one 1310 nm laser, one 1490 nm laser, one 1550 nm laser, one 1625 nm laser, 2 mm InGaAs detector
MBR5-24-3457-2-09FA: one 1310 nm laser, one 1490 nm laser, one 1550 nm laser, one 1650 nm laser, 2 mm InGaAs detector
MBR5-24-0006-5-09FA: one 1625 nm laser, 5 mm Ge detector
MBR5-24-0007-5-09FA: one 1650 nm laser, 5 mm Ge detector
MBR5-24-0050-5-09FA: one 1550 nm laser, 5 mm Ge detector
MBR5-24-0056-5-09FA: one 1550 nm laser, one 1625 nm laser, 5 mm Ge detector
MBR5-24-0057-5-09FA: one 1550 nm laser, one 1650 nm laser, 5 mm Ge detector
MBR5-24-0400-5-09FA: one 1490 nm laser, 5 mm Ge detector
MBR5-24-0406-5-09FA: one 1490 nm laser, one 1625 nm laser, 5 mm Ge detector
MBR5-24-0407-5-09FA: one 1490 nm laser, one 1650 nm laser, 5 mm Ge detector
MBR5-24-0450-5-09FA: one 1490 nm laser, one 1550 nm laser, 5 mm Ge detector
MBR5-24-0456-5-09FA: one 1490 nm laser, one 1550 nm laser, one 1625 nm laser, 5 mm Ge detector
MBR5-24-0457-5-09FA: one 1490 nm laser, one 1550 nm laser, one 1650 nm laser, 5 mm Ge detector
MBR5-24-3000-2-09FA: one 1310 nm laser, 5 mm Ge detector
MBR5-24-3006-5-09FA: one 1310 nm laser, one 1625 nm laser, 5 mm Ge detector
MBR5-24-3007-5-09FA: one 1310 nm laser, one 1650 nm laser, 5 mm Ge detector
MBR5-24-3050-5-09FA: one 1310 nm laser, one 1550 nm laser, 5 mm Ge detector
MBR5-24-3056-5-09FA: one 1310 nm laser, one 1550 nm laser, one 1625 nm laser, 5 mm Ge detector
MBR5-24-3057-5-09FA: one 1310 nm laser, one 1550 nm laser, one 1650 nm laser, 5 mm Ge detector
MBR5-24-3400-5-09FA: one 1310 nm laser, one 1490 nm laser, 5 mm Ge detector
MBR5-24-3406-5-09FA: one 1310 nm laser, one 1490 nm laser, one 1625 nm laser, 5 mm Ge detector
MBR5-24-3407-5-09FA: one 1310 nm laser, one 1490 nm laser, one 1650 nm laser, 5 mm Ge detector
MBR5-24-3450-5-09FA: one 1310 nm laser, one 1490 nm laser, one 1550 nm laser, 5 mm Ge detector
MBR5-24-3456-5-09FA: one 1310 nm laser, one 1490 nm laser, one 1550 nm laser, one 1625 nm laser, 5 mm Ge detector
MBR5-24-3457-5-09FA: one 1310 nm laser, one 1490 nm laser, one 1550 nm laser, one 1650 nm laser, 5 mm Ge detector
MBR5-24-0006-C-09FA: one 1625 nm laser, Cavity
MBR5-24-0007-C-09FA: one 1650 nm laser, Cavity
MBR5-24-0050-C-09FA: one 1550 nm laser, Cavity
MBR5-24-0056-C-09FA: one 1550 nm laser, one 1625 nm laser, Cavity
MBR5-24-0057-C-09FA: one 1550 nm laser, one 1650 nm laser, Cavity
MBR5-24-0400-C-09FA: one 1490 nm laser, Cavity
MBR5-24-0406-C-09FA: one 1490 nm laser, one 1625 nm laser, Cavity
MBR5-24-0407-C-09FA: one 1490 nm laser, one 1650 nm laser, Cavity
MBR5-24-0450-C-09FA: one 1490 nm laser, one 1550 nm laser, Cavity
MBR5-24-0456-C-09FA: one 1490 nm laser, one 1550 nm laser, one 1625 nm laser, Cavity
MBR5-24-0457-C-09FA: one 1490 nm laser, one 1550 nm laser, one 1650 nm laser, Cavity
MBR5-24-3000-C-09FA: one 1310 nm laser, Cavity
MBR5-24-3006-C-09FA: one 1310 nm laser, one 1625 nm laser, Cavity
MBR5-24-3007-C-09FA: one 1310 nm laser, one 1650 nm laser, Cavity
MBR5-24-3050-C-09FA: one 1310 nm laser, one 1550 nm laser, Cavity
MBR5-24-3056-C-09FA: one 1310 nm laser, one 1550 nm laser, one 1625 nm laser, Cavity
MBR5-24-3057-C-09FA: one 1310 nm laser, one 1550 nm laser, one 1650 nm laser, Cavity
MBR5-24-3400-C-09FA: one 1310 nm laser, one 1490 nm laser, Cavity
MBR5-24-3406-C-09FA: one 1310 nm laser, one 1490 nm laser, one 1625 nm laser, Cavity
MBR5-24-3407-C-09FA: one 1310 nm laser, one 1490 nm laser, one 1650 nm laser, Cavity
MBR5-24-3450-C-09FA: one 1310 nm laser, one 1490 nm laser, one 1550 nm laser, Cavity
MBR5-24-3456-C-09FA: one 1310 nm laser, one 1490 nm laser, one 1550 nm laser, one 1625 nm laser, Cavity
MBR5-24-3457-C-09FA: one 1310 nm laser, one 1490 nm laser, one 1550 nm laser, one 1650 nm laser, Cavity

Multimode Configurations, one 850 and one 1310 nm laser:
MBR5-24-8300-C-50FA: Cavity, 50/125 um fiber, FC/APC
MBR5-24-8300-C-62FA: Cavity, 62.5/125 um fiber, FC/APC
MBR5-24-8300-5-50FA: 5 mm Ge detector, 50/125 um fiber, FC/APC
MBR5-24-8300-5-62FA: 5 mm Ge detector, 62.5/125 um fiber, FC/APC
MBR5-24-8300-C-50MA: Cavity, 50/125 um fiber, MTP/APC
MBR5-24-8300-C-62MA: Cavity, 62.5/125 um fiber, MTP/APC
MBR5-24-8300-5-50MA: 5 mm Ge detector, 50/125 um fiber, MTP/APC
MBR5-24-8300-5-62MA: 5 mm Ge detector, 62.5/125 um fiber, MTP/APC


 

Standard Calibration $1,080.00 *
*This is a Web introductory price for one calibration of the JGR MBR5-24. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Coherence Time
Average time for the wave train to lose its phase realtionships

Fiber Bragg Grating (FBG)
A fiber Bragg grating (FBG) is a type of distributed Bragg reflector constructed in a short segment of optical fiber that reflects particular wavelengths of light and transmits all others. This is achieved by adding a periodic variation to the refractive index of the fiber core, which generates a wavelength specific dielectric mirror. A fiber Bragg grating can therefore be used as an inline optical filter to block certain wavelengths, or as a wavelength-specific reflector.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another. Adding information into pulses of light.

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, such as a fiber optic transmission system, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your new JGR MBR5-24 sale price and/or JGR MBR5-24 CALIBRATION

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: