CENTELLAX TR2P1A CALIBRATION and CENTELLAX TR2P1A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the CENTELLAX TR2P1A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Error Detector?
Shop for Comparable Products on our
 used Error Detector page

 
   CENTELLAX TR2P1A   Description / Specification:    
CENTELLAX TR2P1A 1.5 - 12.5 Gb/s Error Detector Remote Rx Head

The Centellax TR2P1A Error Detector is designed to configure the PCB12500 as a bit error rate tester (BERT). Each head connects to the PCB12500 controller through a 1 m cable. This allows it to be located near the signal connection points in the device under test, minimizing cable loss. The modular architecture allows you to purchase only the heads your application requires. Specifications. Signal Configuration: Differential or Single-Ended mode. Data Line Coding: Non-Return to Zero (NRZ). Data Rate: 1.5 to 12.5 Gb/s. Patterns: PRBS 2^n-1, n=7, 10, 15, 23, 31. Input Amplitude: 0.1 to 2.0 V, single ended. Threshold Adjustment: -1.0 V to +1.0 V in 1 mV steps. Termination Voltage: -2.0 V to +2.0 V in 5 mV steps. Delay Range: ±1,000 UI in 1 mUI steps. Autoalign: Set optimum 0/1 threshold and data delay. Search step size range; Threshold: 5 to 20 mV in 1 mV steps, Delay: 5 to 20 mUI in 1 mUI steps, Error Threshold: 1E-6 to 1E-12. BER Measurement Period: 0 to 99,999.999 seconds in 1 msec steps. BER Results: Bit Error Rate, Error Count, Bit Count, Measurement Seconds. Phase Margin: 0.6 UI @ 10 Gb/s, 2^31-1 PRBS. Connectors: 2.92 mm female.



 

Standard Calibration $1,555.00 *
*This is a Web introductory price for one calibration of the CENTELLAX TR2P1A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Communication Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Accuracy
Accuracy is the degree of closeness of measurements of a quantity to that quantity's actual (true) value.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Receiver Sensitivity
Receiver Sensitivity is the optical power required by a receiver for low error signal transmission. In the case of digital signal transmission, the mean optical power is usually quoted in Watts or dBm (decibels referred to 1 milliwatt).


Please contact us for your CENTELLAX TR2P1A CALIBRATION and/or CENTELLAX TR2P1A 1.5 - 12.5 Gb/s Error Detector Remote Rx Head REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: