CENTELLAX TR2P1A CALIBRATION and CENTELLAX TR2P1A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the CENTELLAX TR2P1A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Error Detector?
Shop for Comparable Products on our
 used Error Detector page

 
   CENTELLAX TR2P1A   Description / Specification:    
CENTELLAX TR2P1A 1.5 - 12.5 Gb/s Error Detector Remote Rx Head

The Centellax TR2P1A Error Detector is designed to configure the PCB12500 as a bit error rate tester (BERT). Each head connects to the PCB12500 controller through a 1 m cable. This allows it to be located near the signal connection points in the device under test, minimizing cable loss. The modular architecture allows you to purchase only the heads your application requires. Specifications. Signal Configuration: Differential or Single-Ended mode. Data Line Coding: Non-Return to Zero (NRZ). Data Rate: 1.5 to 12.5 Gb/s. Patterns: PRBS 2^n-1, n=7, 10, 15, 23, 31. Input Amplitude: 0.1 to 2.0 V, single ended. Threshold Adjustment: -1.0 V to +1.0 V in 1 mV steps. Termination Voltage: -2.0 V to +2.0 V in 5 mV steps. Delay Range: ±1,000 UI in 1 mUI steps. Autoalign: Set optimum 0/1 threshold and data delay. Search step size range; Threshold: 5 to 20 mV in 1 mV steps, Delay: 5 to 20 mUI in 1 mUI steps, Error Threshold: 1E-6 to 1E-12. BER Measurement Period: 0 to 99,999.999 seconds in 1 msec steps. BER Results: Bit Error Rate, Error Count, Bit Count, Measurement Seconds. Phase Margin: 0.6 UI @ 10 Gb/s, 2^31-1 PRBS. Connectors: 2.92 mm female.



 

Standard Calibration $1,555.00 *
*This is a Web introductory price for one calibration of the CENTELLAX TR2P1A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Communication Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Decibel (dB)
A unit of measurement of optical power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

PDH
Plesiochronous Digital Hierarchy (PDH) is a transmission system for voice communication using plesiochronous synchronisation. The transmitter adds dummy information bits to allow multiple channels to be bit interleaved. The receiver discards these bits once the signals have been demultiplexed. PDH combines multiple 2 Mb/s (E1) channels in Europe and 1.544 Mb/s (DS1) channels in the US and Japan.

Spectral Width
Spectral Width is the wavelength interval over which the magnitude of all spectral components is equal to or greater than a specified fraction of the magnitude of the component having the maximum value. In optical communications applications, the usual method of specifying spectral width is the full width at half maximum. This is the same convention used in bandwidth, defined as the frequency range where power drops by less than half (at most -3 dB).


Please contact us for your CENTELLAX TR2P1A CALIBRATION and/or CENTELLAX TR2P1A 1.5 - 12.5 Gb/s Error Detector Remote Rx Head REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: