AEMC 1026 CALIBRATION and AEMC 1026 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AEMC 1026 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   AEMC 1026 (2117.72)   Description / Specification:   Spec Sheet 
AEMC 1026 1000V Handheld Megohmmeter

The AEMC 1026 1000V Megohmmeter is a compact, lightweight, battery-operated , hand-held meter. It provides four functional tests. It is a megohmmeter, DC voltmeter, AC voltmeter, ohmmeter and a continuity tester. The AEMC 1026 tests at 250V, 500V and 1000V and measures insulation resistance from 1 kohm to 4000 Mohm.The Model 1026 also features a continuity test range with audible beeper for resistances under 40 ohm, and a 600VAC range for safety voltage check. In addition, the Model 1026 has an ohmmeter to measure from 0.1 ohm to 4000 ohms. Specifications. Test Voltage: 250V (1 kohm to 4000 Mohm), 500V (1 kohm to 4000 Mohm), 1000V (1 kohm to 4000 Mohm). Accuracy <2000 Mohm: 3% of Reading ± 5cts. Accuracy >=2000 Mohm: 5% of Reading ± 5cts. Resistance Measurement Range: Auto ranging to 4000 ohm. Resistance Measurement Resolution: 0.1 to 1 ohm. Resistance Measurement Accuracy: ±1% of Reading ± 5cts. Continuity Measurement Range: Displays and beeps below 40 ohms. Continuity Measurement Protection: 600 Vrms. AC Voltage Measurement Range: 0 to 600V. AC Voltage Accuracy: ±1.5% of Reading + 5 cts. DC Voltage Measurement Range: 0 to 600V. DC Voltage Accuracy: ±1% of Reading + 3 cts.



 

Standard Calibration $295.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the AEMC 1026. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your AEMC 1026 CALIBRATION and/or AEMC 1026 1000V Handheld Megohmmeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: