EXTECH INSTRUMENTS 380580 CALIBRATION and EXTECH INSTRUMENTS 380580 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the EXTECH INSTRUMENTS 380580 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   EXTECH INSTRUMENTS 380580   Description / Specification:   Spec Sheet 
EXTECH INSTRUMENTS 380580 Battery Powered Milliohm Meter

The Extech 380580 Battery Powered Milliohm Meter offers five resistance ranges with resolution as low as 0.1 m-ohm. The 4-wire Kelvin clip connection ensures optimum accuracy. Typical applications include transformer, motor coil, and PC Board resistance measurements. Specifications. Measurement ranges: Five (5) ranges (200.0m, 2000m, 20.00, 200.0, 2000 ohms). 200.0 m-ohm Range Resolution: 0.1 m-ohm, ± 0.5% + 2 digits (accuracy). 2000 m-ohm Range Resolution: 1 m-ohm, ± 0.5% + 2 digits (accuracy). 20.00 ohm Range Resolution: 0.01 ohm, ± 0.5% + 2 digits (accuracy). 200.0 ohm Range Resolution: 0.1 ohm, ± 0.5% + 2 digits (accuracy). 2000 ohm Range Resolution: 1 ohm, ± 0.5% + 2 digits (accuracy). Measurement terminals: 4-Terminal Kelvin type. Sampling Time: Approximately 3 times per second. Display: 1.0" (25 mm) LCD (1999 counts).



 

Standard Calibration $330.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the EXTECH INSTRUMENTS 380580. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your EXTECH INSTRUMENTS 380580 CALIBRATION and/or EXTECH INSTRUMENTS 380580 Battery Powered Milliohm Meter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: