MEGGER MIT200 CALIBRATION and MEGGER MIT200 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the MEGGER MIT200 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   MEGGER MIT200   Description / Specification:    
MEGGER MIT200 500V Insulation and Continuity Tester

The Megger MIT200 insulation and continuity tester is used for installing electrical installations, on both domestic and industrial systems, as well as within site maintenance and service departments. It is also ideal for testing domestic appliances, power tools, transformers, motors, generators, switchgear, electrical panels etc., as well as fixed electrical wiring systems.
Specifications.

Insulation Range.
Nominal test voltages: 500 V (dc).
Measurement range: 10 kΩ - 1000 MΩ on all ranges, Terminal voltage on open circuit (dc) -0 % +25 % of rated voltage.
Test current on load: >1 mA at minimum pass values of insulation as specified in BS 7671, HD 384, IEC 364 and VDE 0413 part 1.

Continuity Range.
Measuring range: 0.01 Ω - 100.0 Ω (0 -50 Ω on analog scale).
Open circuit voltage: 5 V ±1 V.
Short circuit current: 205 mA +10 mA -5 mA >18 mA (10 - 100 Ω).
Accuracy (at 20° C): ±0.01 Ω to 9.99 Ω ± 3 % ±2 digits, 10.0 Ω to 99.9 Ω ± 5 % ±2 digits.
Zero offset adjust: 0 to 9.99 Ω.
Continuity buzzer: Operates at < 2 Ω.
Default voltmeter: >25 V a.c. or d.c. is applied display will operate as a voltmeter.

Voltmeter.
Range: 25 V to 600 V @ 50/60 Hz & dc.
Accuracy: 25 V to 450 V ac/dc ± 1% ± 1 digit, 450 V to 600 V ac ± 2% ± 1 digit.



 

Standard Calibration $210.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the MEGGER MIT200. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your MEGGER MIT200 CALIBRATION and/or MEGGER MIT200 500V Insulation and Continuity Tester REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: