EXTECH INSTRUMENTS EX505 CALIBRATION and EXTECH INSTRUMENTS EX505 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the EXTECH INSTRUMENTS EX505 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   EXTECH INSTRUMENTS EX505   Description / Specification:   Spec Sheet 
EXTECH INSTRUMENTS EX505 True RMS Industrial MultiMeter

The Extech EX505 Heavy Duty True RMS Industrial MultiMeter has a 4,000 count large LCD display, temperature function and waterproof housing. AC/DC Voltage & Current, Resistance, Capacitance, Frequency, Temperature, Duty Cycle, Diode/Continuity. Dual sensitivity frequency functions (electrical/electronic). Specifications. DC Voltage Ranges: 400mV, 4V, 40V, 400V, 1000V. DC Voltage Maximum Resolution: 0.1 mV. DC Voltage Accuracy: ± (0.5% reading + 2 digits) @ 400 mV. AC Voltage Ranges: 400mV, 4V, 40V, 400V, 1000V. AC Voltage Maximum Resolution: 0.1 mV. AC Voltage Accuracy: ± (2.0% reading + 10 digits) @ 400 mV. DC Current Ranges: 400µA, 4000µA, 40mA, 400mA, 10A. DC Current Maximum Resolution: 0.1 µA. DC Current Accuracy: ±(1.0% + 3d) @ 400µA. AC Current Ranges: 400µA, 4000µA, 40mA, 400mA, 10A. AC Current Maximum Resolution: 0.1 µA. AC Current Accuracy: ±(2.5% + 10d) @ 400µA. Resistance Ranges: 400, 4k, 40k, 400k, 4M, 40Mohm. Resistance Maximum Resolution: 0.1 ohm. Resistance Accuracy: ± (1.2% reading + 4 digits) @ 400 ohm. Capacitance Ranges: 4 nF, 40 nF, 400 nF, 4 µF, 40 µF, 100 µF. Capacitance Maximum Resolution: 0.001 nF. Capacitance Accuracy: ±(5.0% reading + 0.5nF) @ 4 nF. Frequency (electrical): 5Hz to 1kHz. Frequency (electronic): 0.001Hz to 10 MHz. Duty Cycle: 0.1% to 99.9%. Duty Cycle Maximum Resolution: 0.1%. Duty Cycle Accuracy: ±(1.2% reading + 2 digits). Temperature Ranges: -4 to 1382°F (-20 to 750°C ). Temperature Maximum Resolution: 0.1°F/°C. Temperature Accuracy: ±(3.0% reading + 5°C /9°F) (probe accuracy not included). Diode Test: Test current of 0.3mA typical, open circuit voltage 1.5V DC typical. Continuity Check: Audible signal will sound if the resistance is less than 100 ohm (approx.), test current <0.3mA.



 

Standard Calibration $75.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the EXTECH INSTRUMENTS EX505. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your EXTECH INSTRUMENTS EX505 CALIBRATION and/or EXTECH INSTRUMENTS EX505 True RMS Industrial MultiMeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: