AMPROBE ACDC-100 CALIBRATION and AMPROBE ACDC-100 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AMPROBE ACDC-100 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   AMPROBE ACDC-100   Description / Specification:   Spec Sheet 
AMPROBE ACDC-100 1000 Amp AC/DC Digital Clamp Multimeter

The Amprobe ACDC-100 1000A AC/DC Digital Clamp Multimeter offers superior AC/DC measurement capabilities, highest product quality and enhanced ergonomics. It features MAX capture function for inrush current measurements (30 ms response). Specifications. DC Voltage: 400.0 mV (Accuracy 0.3% + 3d), 4.000V, 40.00V, 400.0V (Accuracy 0.5% + 3d), 600V (Accuracy 1.0% + 4d). AC Voltage 50 Hz to 500 Hz: 400.0 mV, (Accuracy 4.0% + 4d). AC Voltage 50 Hz to 60 Hz: 4.000V, 40.00V, 400.0V, (Accuracy 1.0% + 4d). AC Voltage 60 Hz to 500 Hz: 4.000V, 40.00V, 400.0V, (Accuracy 1.5% + 4d). AC Voltage 50 Hz to 500 Hz: 600V, (Accuracy 2.0% + 4d). DC Current (Clamp-on) 400.0A: 0.0A to 400.0A (Accuracy 1.5% + 4d). DC Current (Clamp-on) 1000A: 400A to 800A (Accuracy 1.5% + 4d), 800A to 900A (Accuracy 2% + 4d), 900A to 1000A (Accuracy 5% + 30d). AC Current (Clamp-on) 400.0A: 15Hz to 40Hz (Accuracy 2.0% + 5d), 40Hz to 200Hz (Accuracy 1.5% + 5d), 200Hz to 400Hz@ <50A (Accuracy 1.5% + 5d), 400Hz to 1000Hz@ <50A (Accuracy 2% + 5d). AC Current (Clamp-on) 800A: 15Hz to 40Hz@ 400A to 600A (Accuracy 2.0% + 5d), 40Hz to 100Hz@ 400A to 600A (Accuracy 1.5% + 4d), 15Hz to 60Hz@ 600A to 800A (Accuracy 5% + 30d). Resistance: 400.0 ohm (Accuracy 0.8% + 6d), 4.000, 40.00, 400.0 kohm (Accuracy 0.6% + 4d), 4.000 Mohm (Accuracy 1.0% + 4d), 40.00 Mohm (Accuracy 2.0% + 4d). Capacitance: 500.0 nF, 5.000 µF, 50.00 µF, 500.0µF, 3000µF (Accuracy 3.5% + 6d). Display: 3-3/4 digits 4000 counts LCD display. Update Rate: 3 per second nominal.



 

Standard Calibration $255.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the AMPROBE ACDC-100. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your AMPROBE ACDC-100 CALIBRATION and/or AMPROBE ACDC-100 1000 Amp AC/DC Digital Clamp Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: