ANDO VMG-1000 CALIBRATION and ANDO VMG-1000 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANDO VMG-1000 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   ANDO VMG-1000   Description / Specification:    
ANDO VMG-1000 Highmegohm Meter

The Ando VMG-1000 Highmegohm Meter is designed to measure the insulation resistance of high-insulation materials, Up to 2 x 10^10 M-ohm of insulation resistance can be measured. This instrument can also be used as a highly sensitive ammeter to measure current in the range of 5 x 10^-14 to 2 x 10^-5 A. The VMG-1000 incorporates a timer for setting a specific amount of absorption current (charging current, etc.) after the measurement voltage has been applied, and also a GO/NO-GO decision function by means of a comparator, which enables initial setting of a measured value. This facilitates repeated measurements under the same conditions, convenient for component inspection. Use of this instrument will greatly raise efficiency not only in research and development work, but also in assembly line inspections. Specifications. Insulation resistance measurements: 5 M-ohm to 2 x 10^10 M-ohm, in 8 ranges. Accuracy: Meter needle range at 1/3 to 3/4 of full scale (Current scale is 7 to 15 uA), ± 4.5 % for 10^2 to 10^7 M-ohm range, ±8% for 10^8 M-ohm range, ± 10% for 10^9 M-ohm range. Short circuit current: Less than 1 mA. Current measurement: 5 x 10^-8 uA to 20 uA, in 8 ranges. Accuracy for full scale: ± 2 % for 1 to 10^-4 uA range.



 

Standard Calibration $625.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANDO VMG-1000. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your ANDO VMG-1000 CALIBRATION and/or ANDO VMG-1000 Highmegohm Meter REPAIR