YOKOGAWA 701270 CALIBRATION and YOKOGAWA 701270 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA 701270 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope Plug In?
Shop for Comparable Products on our
 used Oscilloscope Plug In page

 
   YOKOGAWA 701270   Description / Specification:    
YOKOGAWA 701270 2-Ch Strain Module (NDIS)

The Yokogawa 701270 Strain Module (NDIS, 2 ch) is used with the DL750, DL750P, SL1400 & SL1000 mainframes. Supports strain NDIS, 2,5, 10 V built-in bridge power supply. Specifications. Input channels: 2. Input types: DC bridge input (automatic balancing), balanced differential input, DC amplifier (floating). Automatic balancing: Electronic auto-balance. Automatic balancing range: ±10,000 ohmSTR (1 gauge method). Bridge voltages: Select 2 V, 5 V, or 10 V. Gauge resistances: 120 ohm to 1000 ohm (bridge voltage 2 V), 350 ohm to 1000 ohm (bridge voltage 2 V, 5 V, 10 V). Gauge rate: 1.90 to 2.20 (variable in 0.01 steps). A/D resolution: 16 bits (48,000 LSB/± FS: Upper = +FS and Lower = -FS). Maximum sample rate: 100 kS/s. Frequency range (-3 dB): DC, up to 20 kHz. DC accuracy: ± (0.5% of FS +5 µSTR). Internal filter: OFF, 1 kHz, 100 Hz, 10 Hz. Input connector: NDIS standard. Accessory (set of solderable connector shells) NDIS connector (A100JC). Recommended bridge head: 701955 (120 ohm), 701956 (350 ohm).



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA 701270. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your YOKOGAWA 701270 CALIBRATION and/or YOKOGAWA 701270 2-Ch Strain Module (NDIS) REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: