YOKOGAWA 701261 CALIBRATION and YOKOGAWA 701261 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA 701261 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope Plug In?
Shop for Comparable Products on our
 used Oscilloscope Plug In page

 
   YOKOGAWA 701261   Description / Specification:    
YOKOGAWA 701261 2-Ch Voltage / Temperature Module

The Yokogawa 701261 Universal Voltage and Temperature Module (2 ch) is used with the DL750, DL750P, SL1400 & SL1000 mainframes. Thermocouples (K, E, J, T, L, U, N, R, S, B, W, iron-doped gold/chromel). Specifications. Input channels: 2. Input signals: Voltage or temperature (thermocouple). AAF (anti-aliasing filter): none. Input couplings: TC (thermocouple), DC, AC, GND. Input types: Isolated unbalanced. Maximum sample rate Voltage: 100 kS/s. Data updating rateTemperature: 500 Hz. A/D conversion resolution: Voltage, 16 bits (24,000 LSB/range), temperature, 0.1°C resolution. Frequency range (-3 dB): Voltage DC, up to 40 kHz. Frequency range (-3 dB): Temperature DC, up to 100 Hz. Input range Voltage (1:1): 50 mV to 200 V range (10 div display, steps of 1, 2, or 5). Input range Temperature K, E, J, T, L, U, N, R, S, B, W, iron doped gold/chromel. Effective measurement range (voltage): 2 times the setting range. DC offset (voltage): 1/2 the setting range. DC accuracy: (voltage) ± (0.25% of range). Input connector: Binding post. Input impedance: Approximately 1 M-ohm. Input filters Voltage: OFF, AUTO (AAF), 4 kHz, 400 Hz, 40 Hz (-12 dB, oct, except AUTO). Input filters Temperature: OFF, 30 Hz, 8 Hz, 2 Hz.



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA 701261. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your YOKOGAWA 701261 CALIBRATION and/or YOKOGAWA 701261 2-Ch Voltage / Temperature Module REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: