YOKOGAWA 701265 CALIBRATION and YOKOGAWA 701265 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA 701265 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope Plug In?
Shop for Comparable Products on our
 used Oscilloscope Plug In page

 
   YOKOGAWA 701265   Description / Specification:    
YOKOGAWA 701265 2-Ch Temperature / High-precision Voltage Module

The Yokogawa 701265 Temperature/high-precision voltage Module (2 ch) is used with the DL750, DL750P, SL1400 & SL1000 mainframes. Thermocouples (K, E, J, T, L, U, N, R, S, B, W, iron-doped gold/chromel), high sensitivity range (1 mV), and low noise (±4 µVtyp). Specifications. Input channels: 2. Input couplings: TC (thermocouple), DC, GND. Input type: Isolated unbalanced. Applicable sensors (Input couplings: TC): K, E, J, T, L, U, N, R, S, B, W, iron doped gold/chromel. Data updating rate: 500 Hz. Frequency range (-3 dB): DC, up to 100 Hz. Voltage accuracy (in voltage mode): ± (0.08% of range + 2 µV). Maximum input voltage (1 kHz or less): 42 V (DC+ACpeak) (CAT I & CAT II, 30 VrmsI). Input range (for 10 div display): 1 mV to 100 V range (in 1/2/5 steps). Input connector: Binding post. Input impedance: Approximately 1 M-ohm. Input filter: OFF, 2 Hz, 8 Hz, 30 Hz. Temperature coefficient (voltage): Zero point ±(0.01% of range)/°C + 0.5 µV/°C (typical value), Gain ±(0.02% of range)/°C (typical value).



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA 701265. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your YOKOGAWA 701265 CALIBRATION and/or YOKOGAWA 701265 2-Ch Temperature / High-precision Voltage Module REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.