YOKOGAWA 701265 CALIBRATION and YOKOGAWA 701265 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA 701265 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope Plug In?
Shop for Comparable Products on our
 used Oscilloscope Plug In page

 
   YOKOGAWA 701265   Description / Specification:    
YOKOGAWA 701265 2-Ch Temperature / High-precision Voltage Module

The Yokogawa 701265 Temperature/high-precision voltage Module (2 ch) is used with the DL750, DL750P, SL1400 & SL1000 mainframes. Thermocouples (K, E, J, T, L, U, N, R, S, B, W, iron-doped gold/chromel), high sensitivity range (1 mV), and low noise (±4 µVtyp). Specifications. Input channels: 2. Input couplings: TC (thermocouple), DC, GND. Input type: Isolated unbalanced. Applicable sensors (Input couplings: TC): K, E, J, T, L, U, N, R, S, B, W, iron doped gold/chromel. Data updating rate: 500 Hz. Frequency range (-3 dB): DC, up to 100 Hz. Voltage accuracy (in voltage mode): ± (0.08% of range + 2 µV). Maximum input voltage (1 kHz or less): 42 V (DC+ACpeak) (CAT I & CAT II, 30 VrmsI). Input range (for 10 div display): 1 mV to 100 V range (in 1/2/5 steps). Input connector: Binding post. Input impedance: Approximately 1 M-ohm. Input filter: OFF, 2 Hz, 8 Hz, 30 Hz. Temperature coefficient (voltage): Zero point ±(0.01% of range)/°C + 0.5 µV/°C (typical value), Gain ±(0.02% of range)/°C (typical value).



 

Standard Calibration $330.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA 701265. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your YOKOGAWA 701265 CALIBRATION and/or YOKOGAWA 701265 2-Ch Temperature / High-precision Voltage Module REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: