YOKOGAWA AQ6373 CALIBRATION and YOKOGAWA AQ6373 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA AQ6373 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Optical Spectrum Analyzer, OSA?
Shop for Comparable Products on our
 used Optical Spectrum Analyzer, OSA page or new Optical Spectrum Analyzer, OSA page

As an alternative New Ridge Technologies offers the NRT-8000, the world’s Smallest Optical Spectrum Analyzer with built in “live wavelength calibration” for C-Band applications.  More
   YOKOGAWA AQ6373 (735303)   Description / Specification:    
YOKOGAWA AQ6373 350 to 1200 nm  Optical Spectrum Analyzer

The Yokogawa AQ6373 Optical Spectrum Analyzer has the ability to provide high speed, accurate analysis of the short wavelength range between 350nm and 1200nm, this OSA is well suited for a broad range of applications. The AQ6373 can accelerate the development and manufacturing of short wavelength lasers, passive devices and LEDs as well as equipment that uses these devices for the biomedical, material processing, consumer product and telecommunications markets. With built in color analysis capabilities and remote command compatibility with the AQ6315, the AQ6373 provides an upgrade of capabilities, speed and performance for current AQ6315 users. The AQ6373 achieves high speed measurements with high accuracy, resolution and sensitivity, even while providing full analysis features. Troublesome calibration steps and the development of external analysis software is no longer required. The advanced monochromator achieves high wavelength resolution and high close-in dynamic range. With the sharper spectral characteristics of the monochromator, spectral signals in close proximity can be separated clearly and measured accurately. The AQ6373 can measure a pulse peak spectrum of a pulsed light signal. Often used in the transmission loop testing of telecommunication systems, and also in the low power measurement at the early stage of laser chip development to catch the peak power of a pulsed signal. Specifications. Wavelength range: 350 to 1200 nm. Span: 0.5 nm to 850 nm (full span), and 0 nm. Wavelength accuracy: ±0.05 nm (633 nm), ±0.20 nm (400 to 1100 nm) (After wavelength calibration with 633 nm He-Ne laser.). Wavelength resolution setting: 0.02, 0.05, 0.1, 0.2, 0.5, 1, 2, 5, 10 nm (full range), and 0.01 nm (400 to 470 nm). Minimum sampling resolution: 0.001 nm. Number of sampling: 101 to 50001, AUTO. High dynamic mode: SWITCH (Sensitivity: MID, HIGH1-3). Level sensitivity: -80 dBm (500 to 1000 nm), -60 dBm (400 to 500 nm, 1000 to 1100 nm) (Typical, Resolution setting: >= 0.2 nm, Averaging: 10 times, Sensitivity: HIGH3). Maximum safe input power: +20 dBm (550 to 1100 nm), +10 dBm (400 to 550 nm) (Total input power). Level accuracy: ±1.0 dB (850 nm, Input level: -20 dBm, Resolution setting: = 0.2 nm, Sensitivity: MID, HIGH1-3, SMF [MFD 5 µm@850 nm, NA0.14]). Level linearity: ±0.2 dB (Input level: -40 to 0 dBm, Sensitivity: HIGH1-3). Dynamic range: 60 dB (Peak ±0.5 nm, Resolution setting: 0.02 nm, 633 nm, Sensitivity: HIGH1-3). Applicable fiber: SM, GI (50/125 µm, 62.5/125 µm), Large core fiber (up to 800 µm). Electrical interface: GP-IB × 2 (standard/controller), RS-232, Ethernet, USB, PS/2 (keyboard), SVGA output, Analog output port, Trigger input port, Trigger output port. Display: 10.4-inch color LCD (Resolution: 800 × 600).



 

Standard Calibration $730.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA AQ6373. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Coherence Length
Average distance over which superimposed waves lose their phase relationships

Linewidth
Linewidth is the width of a spectral line in terms of wavelength, wave number and frequency.

Power Flatness Versus Wavelength
When changing the wavelength at constant power setting and recording the differences between actual and displayed power levels, the power flatness is ± half the span (in dB) between the maximum and the minimum of the measured power levels.

Spectral Width
Spectral Width is the wavelength interval over which the magnitude of all spectral components is equal to or greater than a specified fraction of the magnitude of the component having the maximum value. In optical communications applications, the usual method of specifying spectral width is the full width at half maximum. This is the same convention used in bandwidth, defined as the frequency range where power drops by less than half (at most -3 dB).

Telecom Bands
Optical fiber communications typically operate in a wavelength region corresponding to one of the following Bands. O Band (original): 1260–1360 nm. E Band (extended): 1360–1460 nm. S Band (short wavelengths): 1460–1530 nm. C Band (conventional): 1530–1565 nm. L Band (long wavelengths): 1565–1625 nm. U Band (ultralong wavelengths): 1625–1675 nm


Please contact us for your YOKOGAWA AQ6373 CALIBRATION and/or YOKOGAWA AQ6373 350 to 1200 nm Optical Spectrum Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: