YOKOGAWA 701850 CALIBRATION and YOKOGAWA 701850 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA 701850 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope Plug In?
Shop for Comparable Products on our
 used Oscilloscope Plug In page

 
   YOKOGAWA 701850   Description / Specification:    
YOKOGAWA 701850 High-Speed 10 Ms/s 10-Bit Isolation Module

The Yokogawa 701850 High-Speed 10 Ms/s 10-Bit Isolation Module (1 ch) is used with the DL708 DL708E and DL716 mainframes. Specifications. Input channels: 1. Input couplings: DC, AC, GND. Maximum sample rate: 10 MS/s. A/D resolution: 10 bits, Max. 14 bits (when measuring the box average or average). Input type: Isolation unbalanced. Frequency band (-3 dB): DC, up to 2 MHz. Input range 8 div/display: 20 V/div to 5 mV/div (1-2-5 steps) (main unit only), 200 V/div to 50 mV/div (1-2-5 steps) (when instrument is combined with dedicated probe 700929). Max. input voltage (1 kHz or less): In combination with 700929 probe (between H and L): 850 V (DC + AC peak) (CAT I & II, 600 V rms). Max. allowable in-phase voltage: In combination with 700929 probe (between probe tip H or L and case grounding) 400 V rms (CAT I & II). DC accuracy: 20 V/div to 10 mV/div (main unit only) ±(1.5% of 8 div + offset voltage accuracy). Offset voltage accuracy: ±(0.04% of offset voltage range + 1% of set value). Input impedance: 1 M-ohm ±1%, approximately 30 pF. Connector type: Isolated type BNC connector. Input filter: OFF / 500, 50, 5 kHz / 500 Hz.



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA 701850. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bandwidth
Bandwidth is the difference between the upper and lower frequencies in a contiguous set of frequencies within which a component, link or network will operate.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Noise Figure
Noise Figure the ratio of the signal-to-noise power ratio at the input to the signal-to-noise power ratio at the output.

Ringing
Ringing is an unwanted oscillation of a voltage or current.


Please contact us for your YOKOGAWA 701850 CALIBRATION and/or YOKOGAWA 701850 High-Speed 10 Ms/s 10-Bit Isolation Module REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: