YOKOGAWA 701850 CALIBRATION and YOKOGAWA 701850 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA 701850 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope Plug In?
Shop for Comparable Products on our
 used Oscilloscope Plug In page

 
   YOKOGAWA 701850   Description / Specification:    
YOKOGAWA 701850 High-Speed 10 Ms/s 10-Bit Isolation Module

The Yokogawa 701850 High-Speed 10 Ms/s 10-Bit Isolation Module (1 ch) is used with the DL708 DL708E and DL716 mainframes. Specifications. Input channels: 1. Input couplings: DC, AC, GND. Maximum sample rate: 10 MS/s. A/D resolution: 10 bits, Max. 14 bits (when measuring the box average or average). Input type: Isolation unbalanced. Frequency band (-3 dB): DC, up to 2 MHz. Input range 8 div/display: 20 V/div to 5 mV/div (1-2-5 steps) (main unit only), 200 V/div to 50 mV/div (1-2-5 steps) (when instrument is combined with dedicated probe 700929). Max. input voltage (1 kHz or less): In combination with 700929 probe (between H and L): 850 V (DC + AC peak) (CAT I & II, 600 V rms). Max. allowable in-phase voltage: In combination with 700929 probe (between probe tip H or L and case grounding) 400 V rms (CAT I & II). DC accuracy: 20 V/div to 10 mV/div (main unit only) ±(1.5% of 8 div + offset voltage accuracy). Offset voltage accuracy: ±(0.04% of offset voltage range + 1% of set value). Input impedance: 1 M-ohm ±1%, approximately 30 pF. Connector type: Isolated type BNC connector. Input filter: OFF / 500, 50, 5 kHz / 500 Hz.



 

Standard Calibration $330.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA 701850. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your YOKOGAWA 701850 CALIBRATION and/or YOKOGAWA 701850 High-Speed 10 Ms/s 10-Bit Isolation Module REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: