YOKOGAWA 701852 CALIBRATION and YOKOGAWA 701852 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA 701852 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope Plug In?
Shop for Comparable Products on our
 used Oscilloscope Plug In page

 
   YOKOGAWA 701852   Description / Specification:    
YOKOGAWA 701852 High-voltage 100 kS/s 16-Bit Isolation Module

The Yokogawa 701852 High-voltage 100 kS/s 16-Bit Isolation Module is used with the DL708, DL708E and DL716 mainframes. Specifications. Input channels: 1. Input couplings: AC, DC, GND. Maximum sample rate: 100 kS/s. A/D resolution 16 bits. Input type: Isolation unbalanced. Frequency band (-3 dB): DC to 40 kHz (200 V/div to 100 mV/div), DC to 40 kHz (50 mV/div). Input range: 200 V/div to 50 mV/div (1-2-5 steps) 8 div/display. Max. input voltage (1 kHz or less): 850 V (DC + AC peak) (between signal H and L) (CAT I & II, 600 Vrms). Max. allowable in-phase voltage: 400 Vrms (CAT I & II) (between signal H or L and case grounding). DC accuracy (excluding when Input filter is set to Auto): 200 V/div to 100 mV/div: ±(0.5% of 8 div), 50 mV/div: ±(1% of 8 div). Input impedance: 1 M-ohm ± 1%. Input connector: Safety connector (banana plug). CMRR: 80db (50/60 Hz) or more. Temperature: cofficient (excluding when input filter is set to Auto). Zero point: ±(0.02% of 8div)/°C. Gain: ±(0.02% of 8div)/°C. Input filter (LPF): OFF/4 kHz/400, 40 Hz. FFT anti-aliasing filter: OFF/40 kHz to 20 Hz.



 

Standard Calibration $330.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA 701852. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your YOKOGAWA 701852 CALIBRATION and/or YOKOGAWA 701852 High-voltage 100 kS/s 16-Bit Isolation Module REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: