YOKOGAWA 701853 CALIBRATION and YOKOGAWA 701853 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA 701853 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope Plug In?
Shop for Comparable Products on our
 used Oscilloscope Plug In page

 
   YOKOGAWA 701853   Description / Specification:    
YOKOGAWA 701853 High-resolution 100 kS/s 16-Bit Isolation Module

The Yokogawa 701853 High-resolution 100 kS/s 16-Bit Isolation Module is used with the DL708, DL708E and DL716 mainframes. Specifications. Input channels: 1. Input couplings: AC, DC, GND. Maximum sample rate: 100 kS/s. A/D resolution 16 bits. Input type: Isolation unbalanced. Frequency band (-3 dB): DC to 40 kHz (20 V/div to 10 mV/div), DC to 30 kHz (5 mV/div). Input range: 20 V/div to 5 mV/div (1-2-5 steps) 8 div/display. Max. input voltage (1 kHz or less): 100 V (DC + AC peak) (between signal H and L) (CAT I & II, 70 Vrms). Max. allowable in-phase voltage: 400 Vrms (CAT I & II) (between signal H or L and case grounding). DC accuracy (excluding when Input filter is set to Auto): 20V/div to 20mV/div: ±(0.3% of 8 div), 10mV/div: ±(0.5% of 8 div), 5mV/div: ±(1% of 8 div). Input impedance: 1 M-ohm ± 1%. Input connector: Safety connector (banana plug). CMRR: 80db (50/60 Hz) or more. Temperature: cofficient (excluding when input filter is set to Auto). Zero point: ±(0.02% of 8div)/°C. Gain: ±(0.02% of 8div)/°C. Input filter (LPF): OFF/4 kHz/400, 40 Hz. FFT anti-aliasing filter: OFF/40 kHz to 20 Hz.



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA 701853. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your YOKOGAWA 701853 CALIBRATION and/or YOKOGAWA 701853 High-resolution 100 kS/s 16-Bit Isolation Module REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: